S e c t i o n   6

S U G G E S T E D   I N S T A L L A T I O N

WIL-11320-E-01

 

7

 

WILDEN PUMP & ENGINEERING, LLC

Wilden pumps are designed to meet the performance 
requirements of even the most demanding pumping 
applications.  They have been designed and manufactured 
to the highest standards and are available in a variety of 
wetted-path materials to meet your chemical resistance 
needs.  Refer to the performance section of this manual for 
an in-depth analysis of the performance characteristics of 
your pump.  Wilden offers the widest variety of elastomer 
options in the industry to satisfy temperature, chemical 
compatibility, abrasion resistance and flex concerns.
The suction pipe size should be at least the equivalent or 
larger than the diameter size of the suction inlet on your 
Wilden pump.  The suction hose must be non-collapsible, 
reinforced type as these pumps are capable of pulling a high 
vacuum. Discharge piping should also be the equivalent 
or larger than the diameter of the pump discharge which 
will help reduce friction losses.  It is critical that all fittings 
and connections are airtight or a reduction or loss of pump 
suction capability will result.
INSTALLATION: Months of careful planning, study 
and selection efforts can result in unsatisfactory pump 
performance if installation details are left to chance.
Premature failure and long-term dissatisfaction can be 
avoided if reasonable care is exercised throughout the 
installation process.
LOCATION: Noise, safety and other logistical factors usually 
dictate where equipment will be situated on the production 
floor. Multiple installations with conflicting requirements 
can result in congestion of utility areas, leaving few choices 
for additional pumps.
Within the framework of these and other existing conditions, 
every pump should be located in such a way that six key factors 
are balanced against each other to maximum advantage.
ACCESS: First of all, the location should be accessible. If 
it is easy to reach the pump, maintenance personnel will 
have an easier time carrying out routine inspections and 
adjustments. Should major repairs become necessary, ease 
of access can play a key role in speeding the repair process 
and reducing total downtime.
AIR SUPPLY: Every pump location should have an air line large 
enough to supply the volume of air necessary to achieve the 
desired pumping rate. Use air pressure up to a maximum of 
8.6 bar (125 psig) depending on pumping requirements.
For best results, the pumps should use a 5µ (micron) air 
filter, needle valve and regulator. The use of an air filter 
before the pump will ensure that the majority of any pipeline 
contaminants will be eliminated.
SOLENOID OPERATION: When operation is controlled by a 
solenoid valve in the air line, three-way valves should be 
used. This valve allows trapped air between the valve and 
the pump to bleed off which improves pump performance. 
Pumping volume can be estimated by counting the number 
of strokes per minute and then multiplying the figure by the 
displacement per stroke.

MUFFLER: Sound levels are reduced below OSHA 
specifications using the standard Wilden muffler. Other 
mufflers can be used to further reduce sound levels, but 
they usually reduce pump performance.
ELEVATION: Selecting a site that is well within the pump’s 
dynamic-lift capability will ensure that loss-of-prime issues will 
be eliminated. In addition, pump efficiency can be adversely 
affected if proper attention is not given to site location.
PIPING: Final determination of the pump site should not be 
made until the piping challenges of each possible location 
have been evaluated. The impact of current and future 
installations should be considered ahead of time to make 
sure that inadvertent restrictions are not created for any 
remaining sites.
The best choice possible will be a site involving the 
shortest and straightest hookup of suction and discharge 
piping. Unnecessary elbows, bends, and fittings should 
be avoided. Pipe sizes should be selected to keep friction 
losses within practical limits. All piping should be supported 
independently of the pump. In addition, the piping should 
be aligned to avoid placing stress on the pump fittings.
Flexible hose can be installed to aid in absorbing the forces 
created by the natural reciprocating action of the pump. If the 
pump is to be bolted down to a solid location, a mounting 
pad placed between the pump and the foundation will assist 
in minimizing pump vibration. Flexible connections between 
the pump and rigid piping will also assist in minimizing 
pump vibration. If quick-closing valves are installed at any 
point in the discharge system, or if pulsation within a system 
becomes a problem, a surge suppressor (SD Equalizer

®

should be installed to protect the pump, piping and gauges 
from surges and water hammer.
If the pump is to be used in a self-priming application, make 
sure that all connections are airtight and that the suction lift is 
within the model’s ability. NOTE: Materials of construction and 
elastomer options have an effect on suction lift parameters. 
Please refer to the performance section for specifics.
When pumps are installed in applications involving flooded 
suction or suction head pressures, a gate valve should be 
installed in the suction line to permit closing of the line for 
pump service.
Pumps in service with a positive suction head are most efficient 
when inlet pressure is limited to 0.5–0.7 bar (7–10 psig). 
Premature diaphragm failure may occur if positive suction 
is 0.7 bar (10 psig) and higher.
SUBMERSIBLE APPLICATIONS: Pro-Flo

®

 SHIFT pumps can 

be used for submersible applications when using the Pro-Flo

®

 

SHIFT's single-point exhaust option.
ALL WILDEN PUMPS ARE CAPABLE OF PASSING SOLIDS.  
A STRAINER SHOULD BE USED ON THE PUMP INTAKE TO 
ENSURE THAT THE PUMP'S RATED SOLIDS CAPACITY IS 
NOT EXCEEDED.
CAUTION: DO NOT EXCEED 8.6 BAR (125 PSIG) AIR SUPPLY 
PRESSURE [3.4 BAR (50 PSIG) FOR UL-LISTED MODELS.

Содержание Wilden PS Brahma Series

Страница 1: ...wildenpump com EOM Engineering Operation Maintenance Where Innovation Flows PS Brahma Metal Pump...

Страница 2: ...SYSTEM 3 SECTION 4 DIMENSIONAL DRAWING 4 SECTION 5 PERFORMANCE PS Brahma Performance PS810 Brahma Rubber Fitted 5 PS1510 Brahma Rubber Fitted 5 Suction Lift Curves 6 SECTION 6 SUGGESTED INSTALLATION...

Страница 3: ...sult Pump valves and containers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard CAUTION Do not exceed 8 6 bar 125 p...

Страница 4: ...Flange 0677 Horizontal Center Ported NPT Threaded 0678 Horizontal Center Ported BSPT Threaded 0687 Horizontal Center Ported NPT Threaded Single Point Exhaust 0688 Horizontal Center Ported BSPT Threade...

Страница 5: ...tmos pheric pressure forces fluid into the inlet manifold of the pump The inlet check valve is forced off its seat allowing the fluid being pumped to fill the liquid chamber FIGURE 3 At completion of...

Страница 6: ...L D R A W I N G S PS1510 METAL DIMENSIONS ITEM METRIC mm STANDARD inch A 874 34 4 B 107 4 2 C 422 16 6 D 658 25 9 E 754 29 7 F 757 29 8 G 46 1 8 H 104 4 1 J 411 16 2 K 716 28 2 L 401 15 8 M 704 27 7...

Страница 7: ...chart were determined by pumping water For optimum life and performance pumps should be specified so that daily operation parameters will fall in the center of the pump s performance curve PS1510 META...

Страница 8: ...m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pum...

Страница 9: ...es pump performance Pumping volume can be estimated by counting the number of strokes per minute and then multiplying the figure by the displacement per stroke MUFFLER Sound levels are reduced below O...

Страница 10: ...located at the top and the fluid discharge is located at the bottom of the pump AIR OPERATED PUMPS To stop the pump from operating in an emergency situation simply close the shut off valve user suppl...

Страница 11: ...necessary repairs and replacements Over a period of time such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime In addition accurat...

Страница 12: ...nch 9 16 Wrench 5 8 Wrench CAUTION Before any maintenance or repair is attempted the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump Disconne...

Страница 13: ...ce Step 6 Inspect manifold gasket flap valve seat and seat gasket for nicks gouges chemical attack or abrasive wear Step 7 Using a 9 16 wrench remove the fasteners that connect the remaining inlet elb...

Страница 14: ...he liquid chamber Step 13 Using a 7 16 wrench remove the flap valve assembly from the liquid chamber Inspect flap valves for nicks gouges chemical attack or abrasive wear NOTE Replace worn parts with...

Страница 15: ...onnect the liquid chambers to the center section Step 18 Remove the liquid chamber to expose the diaphragm and outer piston Step 19 Next remove center section assembly from pump stand Step 20 Using tw...

Страница 16: ...hragm piston assembly bumper and main shaft from the center section Step 23 Remove the inner piston from the diaphragm piston assembly by turning counterclockwise P U M P D I S A S S E M B L Y WIL 113...

Страница 17: ...pumps utilize a revolutionary Pro Flo SHIFT air distribution system Proprietary composite seals reduce the coefficient of friction and allow the Pro Flo SHIFT to run lube free The Pro Flo SHIFT air d...

Страница 18: ...rings and replace if necessary Step 9 Using the appropriate sized wrench loosen the fasteners and lift away remaining air chamber and center block gasket from center section Replace gasket if necessa...

Страница 19: ...ool bore Inspect and replace if necessary Step 12 Using an appropriate sized wrench remove the pilot exhaust muffler Inspectfordamageorcontamination and replace if necessary Step 14 Lift away muffler...

Страница 20: ...ol and gently sliding the spool out of the air valve body Inspect seals for signs of wear and replace the entire air valve assembly if necessary Re insert the spool immediately into air valve body aft...

Страница 21: ...amaging the inside surface of the new seal With a new seal in hand place the two legs of the needle nose pliers inside the seal ring See Figure A Open the pliers as wide as the seal diameter will allo...

Страница 22: ...N O T E S...

Страница 23: ...WILDEN PUMP ENGINEERING LLC 21 WIL 11320 E 01 S e c t i o n 8 E X P L O D E D V I E W P A R T S L I S T I N G PS810 BRAHMA E X P L O D E D V I E W LW0282 REV B B C A...

Страница 24: ...t 2 08 5215 01 08 5215 02 25 T Section NPT 2 08 5175 01 08 5175 02 T Section BSPT 2 08 5175 01 14 08 5175 02 14 26 Elbow Discharge 2 08 5255 01 08 5255 02 27 Left Hand Foot 2 08 5546 08 08 5546 08 28...

Страница 25: ...WILDEN PUMP ENGINEERING LLC 23 WIL 11320 E 01 PS1510 BRAHMA E X P L O D E D V I E W E X P L O D E D V I E W P A R T S L I S T I N G LW0285 REV B B C A...

Страница 26: ...n ANSI 2 15 5175 01 15 5175 02 T Section DIN 2 15 5176 01 15 5176 02 26 Elbow Discharge 2 15 5255 01 15 5255 02 27 Left Hand Foot 2 15 5546 08 15 5546 08 28 Right Hand Foot 2 15 5545 08 15 5545 08 29...

Страница 27: ...1 08 1305 51 Buna N 08 1012 52 08 1395 52 08 1401 52 08 1185 52 08 1195 52 08 1305 52 LW0283 Rev B PS1510 BRAHMA MATERIAL DIAPHRAGMS FLAP VALVE GASKETS SEAT GASKETS MANIFOLD VALVES FLAP PADS FLAP VALV...

Страница 28: ...N O T E S...

Страница 29: ...N O T E S...

Страница 30: ...N O T E S...

Страница 31: ...s for warranty consideration and must be accompanied by the appropriate MSDS for the product s involved A Return Goods Tag obtained from an authorized Wilden distributor must be included with the item...

Страница 32: ...e Innovation Flows PSG 22069 Van Buren St Grand Terrace CA 92313 5607 P 1 909 422 1730 F 1 909 783 3440 wildenpump com Copyright 2017 PSG ADoverCompany PSG reserves the right to modify the information...

Отзывы: