PSG Wilden PS Brahma Series Скачать руководство пользователя страница 3

WIL-11320-E-01 

WILDEN PUMP & ENGINEERING, LLC

   CAUTION: Do not apply compressed air to the 

exhaust port — pump will not function.

   CAUTION: Do not over-lubricate air supply — 

excess lubrication will reduce pump performance. 
Pump is pre-lubed.

  TEMPERATURE LIMITS:

 

Acetal 

–29°C to 82°C  –20°F to 180°F

 

Buna-N 

–12°C to 82°C 

10°F to 180°F

 Geolast

®

 

–40°C to 82°C  –40°F to 180°F

 

Neoprene 

 –18°C to 93°C 

0°F to 200°F

 Nordel

®

 EPDM 

–51°C to 138°C  –60°F to 280°F

 

Nylon 

 –18°C to 93°C 

0°F to 200°F

 

PFA 

–7°C to 107°C  45°F to 225°F

 

Polypropylene 

 0°C to 79°C  

32°F to 175°F

 

Polyurethane 

–12°C to 66°C  

10°F to 150°F

 

PVDF 

–12°C to 107°C  10°F to 225°F

 

Saniflex™ 

–29°C to 104°C  –20°F to 220°F

 

SIPD PTFE with EPDM-backed 

4°C to 137°C  40°F to 280°F

 

SIPD PTFE with Neoprene-backed  4°C to 93°C 

40°F to 200°F

 PTFE 

1

 

4°C to 104°C  40°F to 220°F

 Viton

®

 FKM 

–40°C to 177°C  –40°F to 350°F

 

Wil-Flex™ 

–40°C to 107°C  –40°F to 225°F

 NOTE: Not all materials are available for all 
models. Refer to Section 2 for the material 
options available for your pump.

   CAUTION: When choosing pump materials, be 

sure to check the temperature limits for all wetted 
components. Example: Viton

®

 has a maximum 

limit of 177°C (350°F), but polypropylene has a 
maximum limit of only 79°C (175°F).

   CAUTION: Maximum temperature limits are 

based upon mechanical stress only. Certain 
chemicals will significantly reduce maximum 
safe operating temperatures. Consult Chemical 
Resistance Guide for chemical compatibility and 
temperature limits.

   WARNING: Prevent static sparking — If static 

sparking occurs, fire or explosion could result. 
Pump, valves and containers must be grounded 
to a proper grounding point when handling 
flammable fluids and whenever discharge of 
static electricity is a hazard.

   CAUTION: Do not exceed 8.6 bar (125 psig) air 

supply pressure.

   CAUTION: The process fluid and cleaning fluids 

must be chemically compatible with all wetted 
pump components. Consult Chemical Resistance 
Guide.

   CAUTION: Do not exceed 82°C (180°F) air inlet 

temperature for Pro-Flo

®

 SHIFT models.

   CAUTION: Pumps should be thoroughly flushed 

before installing into process lines. FDA- and 
USDA-approved pumps should be cleaned and/
or sanitized before being used.

   CAUTION: Always wear safety glasses when 

operating pump. If diaphragm rupture occurs, 
material being pumped may be forced out air 
exhaust.

   CAUTION: Before any maintenance or repair is 

attempted, the compressed air line to the pump 
should be disconnected and all air pressure 
allowed to bleed from pump. Disconnect all 
intake, discharge and air lines. Drain the pump 
by allowing any fluid to flow into a suitable 
container.

   CAUTION: Blow out air line for 10 to 20 seconds 

before attaching to pump to make sure all pipeline 
debris is clear. Use an in-line air filter. A 5μ 
(micron) air filter is recommended.

   NOTE: Before starting disassembly, mark a line 

from each liquid chamber to its corresponding air 
chamber. This line will assist in proper alignment 
during reassembly.

   CAUTION: Pro-Flo

®

 SHIFT is available in 

both single-point exhaust (submersible) and 
standard (non-submersible) options. Do not use 
standard Pro-Flo

®

 SHIFT models in submersible 

applications.

   CAUTION: Tighten all hardware prior to installation.

4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1") models only.

S e c t i o n   1

C A U T I O N S — R E A D   F I R S T !

Содержание Wilden PS Brahma Series

Страница 1: ...wildenpump com EOM Engineering Operation Maintenance Where Innovation Flows PS Brahma Metal Pump...

Страница 2: ...SYSTEM 3 SECTION 4 DIMENSIONAL DRAWING 4 SECTION 5 PERFORMANCE PS Brahma Performance PS810 Brahma Rubber Fitted 5 PS1510 Brahma Rubber Fitted 5 Suction Lift Curves 6 SECTION 6 SUGGESTED INSTALLATION...

Страница 3: ...sult Pump valves and containers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard CAUTION Do not exceed 8 6 bar 125 p...

Страница 4: ...Flange 0677 Horizontal Center Ported NPT Threaded 0678 Horizontal Center Ported BSPT Threaded 0687 Horizontal Center Ported NPT Threaded Single Point Exhaust 0688 Horizontal Center Ported BSPT Threade...

Страница 5: ...tmos pheric pressure forces fluid into the inlet manifold of the pump The inlet check valve is forced off its seat allowing the fluid being pumped to fill the liquid chamber FIGURE 3 At completion of...

Страница 6: ...L D R A W I N G S PS1510 METAL DIMENSIONS ITEM METRIC mm STANDARD inch A 874 34 4 B 107 4 2 C 422 16 6 D 658 25 9 E 754 29 7 F 757 29 8 G 46 1 8 H 104 4 1 J 411 16 2 K 716 28 2 L 401 15 8 M 704 27 7...

Страница 7: ...chart were determined by pumping water For optimum life and performance pumps should be specified so that daily operation parameters will fall in the center of the pump s performance curve PS1510 META...

Страница 8: ...m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pum...

Страница 9: ...es pump performance Pumping volume can be estimated by counting the number of strokes per minute and then multiplying the figure by the displacement per stroke MUFFLER Sound levels are reduced below O...

Страница 10: ...located at the top and the fluid discharge is located at the bottom of the pump AIR OPERATED PUMPS To stop the pump from operating in an emergency situation simply close the shut off valve user suppl...

Страница 11: ...necessary repairs and replacements Over a period of time such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime In addition accurat...

Страница 12: ...nch 9 16 Wrench 5 8 Wrench CAUTION Before any maintenance or repair is attempted the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump Disconne...

Страница 13: ...ce Step 6 Inspect manifold gasket flap valve seat and seat gasket for nicks gouges chemical attack or abrasive wear Step 7 Using a 9 16 wrench remove the fasteners that connect the remaining inlet elb...

Страница 14: ...he liquid chamber Step 13 Using a 7 16 wrench remove the flap valve assembly from the liquid chamber Inspect flap valves for nicks gouges chemical attack or abrasive wear NOTE Replace worn parts with...

Страница 15: ...onnect the liquid chambers to the center section Step 18 Remove the liquid chamber to expose the diaphragm and outer piston Step 19 Next remove center section assembly from pump stand Step 20 Using tw...

Страница 16: ...hragm piston assembly bumper and main shaft from the center section Step 23 Remove the inner piston from the diaphragm piston assembly by turning counterclockwise P U M P D I S A S S E M B L Y WIL 113...

Страница 17: ...pumps utilize a revolutionary Pro Flo SHIFT air distribution system Proprietary composite seals reduce the coefficient of friction and allow the Pro Flo SHIFT to run lube free The Pro Flo SHIFT air d...

Страница 18: ...rings and replace if necessary Step 9 Using the appropriate sized wrench loosen the fasteners and lift away remaining air chamber and center block gasket from center section Replace gasket if necessa...

Страница 19: ...ool bore Inspect and replace if necessary Step 12 Using an appropriate sized wrench remove the pilot exhaust muffler Inspectfordamageorcontamination and replace if necessary Step 14 Lift away muffler...

Страница 20: ...ol and gently sliding the spool out of the air valve body Inspect seals for signs of wear and replace the entire air valve assembly if necessary Re insert the spool immediately into air valve body aft...

Страница 21: ...amaging the inside surface of the new seal With a new seal in hand place the two legs of the needle nose pliers inside the seal ring See Figure A Open the pliers as wide as the seal diameter will allo...

Страница 22: ...N O T E S...

Страница 23: ...WILDEN PUMP ENGINEERING LLC 21 WIL 11320 E 01 S e c t i o n 8 E X P L O D E D V I E W P A R T S L I S T I N G PS810 BRAHMA E X P L O D E D V I E W LW0282 REV B B C A...

Страница 24: ...t 2 08 5215 01 08 5215 02 25 T Section NPT 2 08 5175 01 08 5175 02 T Section BSPT 2 08 5175 01 14 08 5175 02 14 26 Elbow Discharge 2 08 5255 01 08 5255 02 27 Left Hand Foot 2 08 5546 08 08 5546 08 28...

Страница 25: ...WILDEN PUMP ENGINEERING LLC 23 WIL 11320 E 01 PS1510 BRAHMA E X P L O D E D V I E W E X P L O D E D V I E W P A R T S L I S T I N G LW0285 REV B B C A...

Страница 26: ...n ANSI 2 15 5175 01 15 5175 02 T Section DIN 2 15 5176 01 15 5176 02 26 Elbow Discharge 2 15 5255 01 15 5255 02 27 Left Hand Foot 2 15 5546 08 15 5546 08 28 Right Hand Foot 2 15 5545 08 15 5545 08 29...

Страница 27: ...1 08 1305 51 Buna N 08 1012 52 08 1395 52 08 1401 52 08 1185 52 08 1195 52 08 1305 52 LW0283 Rev B PS1510 BRAHMA MATERIAL DIAPHRAGMS FLAP VALVE GASKETS SEAT GASKETS MANIFOLD VALVES FLAP PADS FLAP VALV...

Страница 28: ...N O T E S...

Страница 29: ...N O T E S...

Страница 30: ...N O T E S...

Страница 31: ...s for warranty consideration and must be accompanied by the appropriate MSDS for the product s involved A Return Goods Tag obtained from an authorized Wilden distributor must be included with the item...

Страница 32: ...e Innovation Flows PSG 22069 Van Buren St Grand Terrace CA 92313 5607 P 1 909 422 1730 F 1 909 783 3440 wildenpump com Copyright 2017 PSG ADoverCompany PSG reserves the right to modify the information...

Отзывы: