23/28
NT 1004-C00 03 18 SLC12 i - SLC18 i - SLC12 i HT - SLC18 i HT e
10.1 Discharge port
• Unscrew the 6 screws
416
.
• Turn the front cover
405
so as to position the outlet port
in the desired position.
• Tighten the 6 screws
416
.
• Make sure that the seal
205
is secured in its housing.
Secure it with a grease that is compatible with the
transferred product if necessary.
10.2 Suction port
Consult us.
10.3 Flanges dismantling
• Remove the three screws
136
.
Push back flange
114
against manifold or end cover.
• Remove ring
148
from manifold or end cover groove.
10.4 Flanges reassembly
• Put flange
114
against manifold or end cover with the
three counter-bores visible.
• Put ring
148
in manifold or end cover groove (it should
take its place thanks to its elasticity).
• Pull flange
114
until ring 148 is no longer visible.
• Put three screws
136
and tight them with Loctite
®
243*
thread lock or equivalent.
• Orientate flange to match counter flange holes position
(flange must rotate freely).
WARNING
BE CAREFUL WITH THE WEIGHT OF THE
PARTS WHEN THEY ARE BEING REMOVED.
The weight ot the parts
can be dangerous and
may provoke bodily
injuries or material
damages.
10. CHANGING THE ORIENTATION OF THE PORTS
*
Loctite
®
is a registered trademark.