Installation Manual
LazerData
®
12000 Scanner
Installation - 2.13
2.7.2
Main serial interface
The signals, relative to the following serial interface types, are available on the
input/output connector –
EIA RS232
EIA RS485-NONPOLLED
EIA RS485-POLLED (for connection with PSC Automation multiplexer)
20-mA PASSIVE CURRENT LOOP
The LazerData 12000 Scanner automatically recognizes the type of interface
selected at each scanner power up.
If the recognized interface type is not compatible with the current communication
handshaking, then the system defaults to the XON/XOFF protocol.
The parameters of the interface selected (baud rate, data bits, etc.) can be
configured using the LDHOST utility program or Host Mode programming. For
more details refer to the section "Main Interface Menu" in the LDHOST Help
Online.
Details regarding the connections and use of the main interface selection are given
in the next sections.
RS232 interface
The serial interface is used in this case for point-to-point connections. It handles
communication with the host computer and allows both transmission of code data
and the configuration of the scanner. This is the default interface.
The following pins of the 25-pin connector are used for RS232 interface
connection:
Pin
Name
Function
2
TX232
Transmitted Data
3
RX232
Received Data
4
RTS232
Request To Send
5
CTS232
Clear To Send
7
SGND
Signal Ground
Содержание LazerData 12000 Series
Страница 2: ...LazerData 12000 Series Bar Code Scanner Installation Manual...
Страница 11: ...x...
Страница 17: ...LazerData 12000 Scanner Installation Manual 1 6 General Features...
Страница 53: ...LazerData 12000 Scanner Installation Manual 4 2 Maintenance...
Страница 55: ...LazerData 12000 Scanner Installation Manual 5 2 Service and Warranty...