4
Smart Gate Series
Rev022520
© 2020 PS Industries
®
Incorporated. All Rights Reserved.
Installation
Clearance opening measured
from inside edge of baseplate
to baseplate
CONCRETE FLOOR ANCHOR INFO:
MIN. 3000 PSI CONCRETE
4" MIN. CONCRETE THICKNESS
3" MIN. EDGE DISTANCE (ALL SIDES)
IMPORTANT!
Follow Anchor Manufacturer's technical data manual/installation instructions for installation
requirements and proper installation procedures.
Field concrete foundation design and complete consolidation of concrete surrounding embedded
item(s) anchorage points
NOT
by PS Safety Access
.
Step 1
Illustration
VI. Smart Gate Installation
NOTICE
Colored circle decals are provided for easier installation, remove once install is complete. Refer to parts list
on Page 3 for item numbers and descriptions.
NOTICE
Base plates are slotted to allow adjustment for alignment.
STEP 1.
Mark holes for the Gate Post (
red decal
) and anchor with concrete floor anchors.
a. Measure and mark the center of the wall opening, using the Gate Size Reference Table to assist in
centering the gate on the wall opening. (Gate Size Reference Drawing on Page 15).
Door Opening
this side of
Gate Post
1
10.4
Red
Decal
SG SIZE REFERENCE TABLE
CLEAR OPENING WIDTHS
CLEARANCE HEIGHT
SG-96-PCY*
84”, 96”, OR 108”
130
1
/
4
” - 154
1
/
4
”
*SG-96-PCY:
a. Adjustable from a minimum of 84” to a maximum 108” clear opening.
b. Gate will fit 84”, 96”, and 108” doors.