PerfectWave PowerPlant 10 Back Panel w/ duplex outlets
1) Front panel lighted logo button - When pressed so it is illuminated, the outlets operate as shown on the front panel
display. When pressed so it is not illuminated, the regenerator circuitry is still powered and operating. However,
display and outlets are turned off unless confi gured to be always on.
2) IR remote receiver lens - This is where the signals from the P10 remote control are received.
3) Touch screen display - See operation details elsewhere in this manual
4) Back panel power switch - Pressing the ‘O’ mark on the power switch removes line power to the P10. Pressing the
‘I’ mark applies line power to the P10.
5) Fuse - If replacement is required, for100V or 120V P10 units, use a T250V~ 5A type H fuse. For 230V units use a
T250V~ 3A type H fuse.
6) IEC power inlet connector - Use a 3 conductor 1.5mm cord rated for 250V, 75°C minimum.
7) Circuit breaker - Press to reset
8) Duplex style output connector
9) SD (memory) card socket - Used for fi rmware upgrades
10) Ethernet connection - Uses RJ45 connector. For connection to a Local Area Network (LAN), or to the Internet.
Used for enhanced control and/or monitoring performance of P10.
11) Trigger out port - Uses a 3.5mm tip sleeve connector. The tip is positive. Trigger out provides a 12VDC signal that
follows the condition of the front panel Logo button.
12) Trigger in port - Uses a 3.5mm tip sleeve connector. The tip is positive. A 5VDC to 15VDC signal turns a unit that
is currently in the off state (Logo button not illuminated) to the on state. Removing the trigger in signal is equivalent to
turning the Logo button off. This state of the trigger in port is overridden by the front panel display/Logo button, or the
remote control.
13) Non duplex output connector - The style shown is a Schuko outlet. Other styles are available
Schuko Rear Panel
View
2
2
12
11
10 9
13