PARTS LISTING

 

Description 

Part Number 

Number in kit

 
 

CSS10 Box 

7S10T-42IA-P19 

1

 

Salt Generator Bracket 

202199 

1

 

Salt Generator Cell 

600211 

1

 

Saddle Clamp Assembly 

201155 

2

 

Injector 

600002 

1

 

Plastic Clamp (black) 

20185 

4

 

¾” Metal Hose clamp 

20067 

4

 

¼” Braided Hose 

20260 

120 inches

 

¼” Braided Hose 

 

 

(Cell Maintenance) 

20260 

24 inches

 

¾” Clear Hose 

20264 

120 inches

 

Check Valve (1/4”  by ¼”) 

20214 

1

 

White ½” by 3” PVC Pipe 

20314 

1

 

Gasket, Saddle Clamp 

400078 

2

 

Gasket, Saddle Clamp, Barb 

400076 

2

 

Gasket, Saddle Foot 

400018 

4

ADDITIONAL SAFETY INSTRUCTIONS

NOTE: When the Pump system is shut down you must also shut down the Salt Generator System. 

1.   Your CSS-10 must be installed in accordance with the installation instructions and the Figures/Diagrams provided in this manual.

2.  To have both your Pump system, and the CSS-10 operate properly together as a unit you should wire the two systems together.

3.  The Salt Cell MUST be mounted vertically.

4.  Use only the power cord (DC Voltage) provided with the Ozonator/Salt Generator System to power up the Salt Cell.

IMPORTANT NOTES:

Salt Level Testing:

1.  You should test the salt level of your pool before calculating the salt requirement.

2.  If a Salt test is not performed you may find later that too much salt will have been added - the Chlorinator may not perform as intended.

3.  If the pool has been treated with other forms of Chlorine – for instance Sodium Chloride – you may already have salt content

General:

1.  Always balance the pH, total Alkalinity and Calcium hardness, otherwise corrosive or scaly conditions may result, which will lead to equipment  

   inefficiency or damage. Unbalanced water may cause staining and mineral deposits, chlorine effectiveness may decrease, and bathers may 

  experience discomfort.

2.  Regular testing of the pool waters is recommended. A Free Chlorine level of 0.5ppm (parts per million) to 1.5ppm should be maintained.

3.  

DO NOT USE

  Copper or Bromine based Algaecide products in your pool when the CSS-10 is installed. 

4.   Prozone recommends the pool pump and Salt Generator (see safety note above),  for a minimum of 8 to 12 hours a day. Actual run time 

  will be affected by the chlorine demand from the environment or bathers.

7.  

WARNING:  Always disconnect automatic pool cleaners before adding salt which must be fully dissolved before turning on the 

  pool cleaner.

8.  

Plaster Pools:

  Do not start system until plaster has set for two weeks.

9.  

WARNING:  Baquacil (Biguanide Pools)  must be drained and refilled with fresh water prior to using the CSS-10.

   

10. Read the entire Owner’s Manual.  Additional advice can be obtained from a pool installation professional or from a Prozone sales representative   

 

(

[email protected]

)

 or visit our website at 

www.prozoneint.com

.

Содержание CSS 10

Страница 1: ...t Work 2 Safety Warnings 2 Parts List 3 Important Notes 3 Initial Salt Dosage 4 Initial Salt Dosage Chart 4 Recommended Salt Type and How to Add 4 Cell Maintenance 4 5 Warranty Information and Form Pl...

Страница 2: ...Salt Water Mild salt water is gentle on the eyes and skin In seawater the salinity is approximately 35 000ppm parts per million The human body has a salinity of approximately 4 500 to 6 000ppm while...

Страница 3: ...dded the Chlorinator may not perform as intended 3 If the pool has been treated with other forms of Chlorine for instance Sodium Chloride you may already have salt content General 1 Always balance the...

Страница 4: ...Soda Prussiate of Soda is an anti caking agent which contains iron This type salt may cause yellow stains on your pool bottom if left there without being dissolved 3 WARNING Do not use rock salt which...

Страница 5: ...e pump back on for approximately 1 minute or until Salt Cell is lled with acid 6 Turn the pump off for 15 to 20 minutes to allow the solution to soak the plates 7 Repeat Steps 5 and 6 above until the...

Страница 6: ...______________________________________________________ Supplier telephone No __________________________________________________________________________________________________ Date of installation ___...

Страница 7: ...TART INSTRUCTION GUIDE Please see www prozoneint com to print out the complete Owner s Manual Prozone Pool Products Huntsville AL 35805 256 539 4570 www prozoneint com CSS1 0Complete Sanitation System...

Страница 8: ...sure so water can return to main pipe Diagram 3 Assemble the Saddle Clamp Diagram 4 Attach Saddle Clamp over hole after pump Insert injector into top of Saddle Clamp small ports pointing away from hol...

Страница 9: ...piece of braided hose to check valve Secure with black hose clamp Attach end of braided hose to open port on top of injector Diagram 8 Rubber Bushing 1 1 2 Adapter Upper Neoprene Gasket 7 8 Dia Hole 1...

Страница 10: ...is on when pump is running Turn on Power switch at top of CSS10 Box You must push in knob and turn clockwise to select chlorine production level Diagram 10 Electrical Leads CSS Complete Sanitation Sys...

Страница 11: ...he injector L15 ozone is being injected through the mixing port of the Venturi Injector L11 3 This water enters the Salt Chlorine Generator Cell through the bottom of the Cell L18 L19 4 A low voltage...

Страница 12: ...tion an unpleasant procedure or ozonation Combined chlorines are most often associated with odors eye irritation and other unpleasant side effects of chlorination Installation of a Prozone Ozonator Sa...

Страница 13: ...should be no nitrates in your pool water Most often Nitrates are associated with fertilizers A high level of nitrates may cause a higher than normal demand on Chlorine often lowering the Chlorine leve...

Отзывы: