User Manual
sens07vest
Page 32
May 2020
6.3
Blackout protection
Entering into the diving zone launches the inflation countdown (3
minutes).
The diving and warning zone do not yet offer any functional differ-
ences, except that they can be recognized by different flashing se-
quences on the sens07 head.
The Blackout countdown is launched as soon as the diver is back in
the safe zone and triggers inflation in case the self-test button is
not pressed in time (15 seconds).
There is no other option to stop upcoming inflation except getting
out of the water in time. Please note that the water sensor needs
some seconds to detect missing water.
After pressing the button (confirming no blackout) the sens07vest
is ready for the next dive.
time
Depth
Diving zone
Safe zone
Inflation
3 m
20 m
0 m
IC (Inflation Countdown)
3 min
3 blinks in
Warning zone
Entering diving
zone starts IC
2 blinks in
Dive zone
Returning to
safe zone
stops IC
Missing
confirmation
triggers inflation
Blackout Configuration Mode
Safe zone:
3 m
Diving countdown:
3 min.
Warning zone: 15 m
Blackout countdown: 15 sec.
Diving zone: 20 m
15 m
Warning zone
Blackout
15 sec.
User Manual
sens07vest
May 2020
Page 33
7
Advanced explanations &trouble shooting
7.1
Unsuccessful optical data transfer
A successful optical data transfer is indicated by a blinking green
light after the transfer. The red light or no light at all indicates an
unsuccessful optical data transfer, which may have the following
causes:
•
Display is too far away from the inflator head.
We recommend to touch the sensor head with the display of
the phone to protect the light receiver of the sensor head as
good as possible from light inferences.
•
The optical data transfer is robust against ambient light (for ex-
ample bright sunlight). However, neon tubes and LED lighting
can emit pulsating light that is invisible to the human eye but
can interfere with optical data transmission.
•
Additional display protection or waterproof sleeves for your
mobile phone may interfere with the optical data transfer. In
case of problems, please try If problems occur, please try to
transfer the data without the protective cover.
•
The sens07 app will set the display brightness to 100% before
data transfer. Please check that, as the sens07 app cannot con-
trol the brightness on all Android phones.