5.4

 

Perform Self-Test 

 

Pressing the button in dry condition (outside of the water) will 
launch the self-test which is confirmed immediately by the green 
or red light. 
The red LED indicates an internal problem such as actuator module 
not inserted or already used, battery low, sensor error or other in-
ternal errors. In most cases, the problem is based on an already 
used or wrongly-placed actuator module that needs to be re-
placed. 

Note: The CO

2

 cylinder is excluded from the self-test! 

The amount of blink (green or red) indicate the active mode or pro-
file: 

 

0 flash: Manual mode (off) 

 

1 flash: Profile 1  

 

2 flashes: Profile 2  

 

3 flashes: Profile 3  

 

4 flashes: Timed inflation (option) 

Note: In case of a negative self-test (red LED), the sens07 inflator 
will still do it’s best to function as usual. However, there is a high 
chance of failure and you must not use sens07vest. 

 

 

User Manual 

sens07vest 

May 2020 

 

Page 29 

5.5

 

Location of the manual handle 

Make sure that the manual cord is accessible from outside and that 
the cord runs directly without any diversion to the sens07 base. 
The cord is equipped with a Velcro tag near to the red handle. This 
Velcro tag must be attached to the Velcro closure on the 
sens07vest, so that the handle is always available on the same, 
specified position. 

It is very important that you can feel and find the handle immedi-
ately because you don’t have time to search for it in case of emer-
gency! 

5.6

 

Put on the sens07vest correctly 

Take care that the 2 metal buckles on the side are adjusted cor-
rectly. Don’t pull them too tight so that you can breathe freely. 

Never forget to attach the crotch strap! The uplift of the bladder in 
case of inflation is about 15 kg. 
Without the crotch strap the sens07vest may lift over your head, 
which may be very dangerous! 

5.7

 

Rinse sens07vest after diving 

The sens07vest needs similar maintenance like most scuba dive 
equipment. Please rinse the sens07vest in freshwater. Make sure 
that the water gets into the vest by opening the lower right part of 
the zipper. It is important that the sens07 inflator and CO

2

 cylinders 

are cleaned from saltwater to avoid corrosion. 

Содержание sens07vest

Страница 1: ...User Manual sens07vest May 2020 Page 1 User Manual Mai 2020...

Страница 2: ...Inflation reason report 15 3 2 2 Red LED Battery low 15 4 sens07 app 16 4 1 Introduction 16 4 2 Installation and registration 17 4 3 Tab 1 Profiles 18 4 3 1 Profiles configurator basic 19 4 3 2 Profil...

Страница 3: ...r after the dive in order to prevent inflation of the bladder The sens07vest is designed to protect free divers and spear fisher up to 50 meters under water when using a 95gr CO2 cylinder Be low this...

Страница 4: ...nserted before each dive User Manual sens07vest May 2020 Page 7 1 4 Activation on water contact The sens07 inflator immediately starts its auto supervision when wa ter can be sensed by the integrated...

Страница 5: ...p User Manual sens07vest May 2020 Page 9 1 8 Customization using the sens07 app The inflation parameters and features called profile can be customized using the sens07 app and are wirelessly transferr...

Страница 6: ...ns07vest May 2020 Page 11 2 2 Suspend upcoming inflation while diving Pressing the self test button when the sens07vest is submerged will suspend freeze the risk inflation countdown for the specified...

Страница 7: ...Perform the self test as described after replacing the actuator module User Manual sens07vest May 2020 Page 13 3 LED signals The inflator head has 2 front LED for important information and 3 back LED...

Страница 8: ...self test button Blackout warning Inflation occurred sens07 inflator is functional Timed inflation active Timed inflation standby User Manual sens07vest May 2020 Page 15 3 2 System LEDs on the back s...

Страница 9: ...charge available for IOS and for Android devices and can be downloaded and installed in the usual way from the Apple App store or Android Play store A registration code for private or cooperate users...

Страница 10: ...basic The drowning algorithm is based on 3 depth zones Safe zone Diving zone and Inflation zone A simple inflation countdown starts at the specified value when entering into the Div ing Zone Inflatio...

Страница 11: ...eing at least 10 seconds in the Diving Zone Upcoming inflation can only be stopped by pressing the button Combat diver can disable the LED Signal un der water for this specific profile The last segmen...

Страница 12: ...support if activated 3 After transfer check for the blinking green LED confirming suc cessful data transfer 4 Confirm seeing the green LEDs by clicking Yes on the app 5 Click on Retry in case of no b...

Страница 13: ...d seconds until inflation There are 3 sliders for additional options The countdown start after transfer or on first water contact Countdown aborts when sens07 is taken out of the water Countdown abort...

Страница 14: ...Bladder Verify the bladder for any hole or other kind of dam age It is recommended to inflate the bladder every 2 years to check it for holes Straps Verify if the straps are well sewed and the buckle...

Страница 15: ...e that the manual cord is accessible from outside and that the cord runs directly without any diversion to the sens07 base The cord is equipped with a Velcro tag near to the red handle This Velcro tag...

Страница 16: ...ne starts IC Remaining in safe zone resets IC Entering diving zone starts IC Expired IC inflates sens07vest 0 min 1 min Basic Configuration Mode Safe zone 3 m Inflation countdown 2 min Diving zone 20...

Страница 17: ...m Blackout countdown 15 sec Diving zone 20 m 15 m Warning zone Blackout 15 sec User Manual sens07vest May 2020 Page 33 7 Advanced explanations trouble shooting 7 1 Unsuccessful optical data transfer A...

Страница 18: ...uration of the inflator head can be tested without the vest CO2 cylinder base unit and actuator module Just immerse the inflator head into water and observe the LED for water zone indicator and inflat...

Отзывы: