TROUBLESHOOTING
Room Sensor Error! : Built-in sensor short-circuit or disconnected.
Floor Sensor Error! : Floor sensor short-circuit or disconnected.
6. Switching Differential:
The number of degrees the temperature has to change before the unit switches
on/off. The default is 1 degree so if the temperature is set to 21 degrees the thermostat will
switch on at 20.5 degrees and off at 21.5 degrees. 0.5 degrees either side of 21.
7. Temp unit:
°F and °C can be selected.
8: Sensor selection
Room
sensor:
Run by room sensor.
Floor sensor:
Run by floor sensor.
Both
sensors:
Run by room sensor with floor temp limit.
9. Schedule:
Select a weekly schedule for the event.
7:
each day from Mon to Sun can be set individually.
5+1+1:
Mon to Fri have the same events, Sat and Sun can be set individually.
10. Output delay:
This option help you avoid inadvertent operation on heating.
11. Adaptive function:
After several days of installation and use, Adaptive function ensures that the required
temp has already been reached when the next event begins.
12. Open window:
This function only works when room sensor or both sensors is selected. The thermostat
with this function will shut o
ff
automatically for 15 min when the window opens, as it can detect that the
room temp plummets.
13&14. Energy use:
This option allows you to enter the various data used to calculate energy use.
15. Factory Reset:
All parameters are restored to default values.