ENGLISH | AS-5030
19
Protection class
IP 20, for dry rooms only
Battery (window contact) 1 x type CR 123A
Batteries (transmitter
3 x size AA /Mignon/LR6
module thermal sensor) alkaline
Technical changes may be made at short notice without
advance warning as part of our product updates and device
optimisation.
SAFETY NOTES
The warranty will be null and void in case of damages arising
from violations of these operating instructions. We are not
liable for consequential damages!
We accept no liability for material damages or injuries arising
from inappropriate use or violation of the safety instructions.
In such cases all warranty claims are null and void!
Do not use this product in hospitals or other medical
facilities. Although this device transmits only relatively weak
radio signals, the signals may in such locations result in
malfunctioning of systems critical to life. The same may
apply to other areas.
For reasons of safety and licensing (CE), unauthorised
conversion and /or modification of the product is prohibited.
Do not take the product apart!
There is a danger of lethal electric shock!
Do not leave packaging material lying about since plastic
foils and pockets and polystyrene parts etc. could be lethal
toys for children.
seconds later. The test button can then be released and the
receiver is returned to the original state, i.e. all transmitters
must be reprogrammed.
Test function
Using the test button on the receiver, you can test the
function of the relay in the receiver. If the test button is
pressed briefly, the relay turns on for approx. one second and
three beeps can be heard. (click-beeb-click-beep-beep) This
function is only available when the window is closed and the
stove in operation.
CE Notes
Strong electric, magnetic or high-frequency fields (discharge,
mobile phones, wireless systems, mobile phones, micro-
waves) may cause the device(s) to malfunction.
CE Compliance
We confirm the conformity of the devices according to the
European Directive 2004/108/EC on electromagnetic
compatibility and the Low Voltage Directive 2006/95/EC.
The radio approval is certified according to the EC R & TTE
Directive 1999/5/EC.
Technical data
Mains voltage (receiver) 230 V ~, 50/60 Hz,
approx. 2 W
Breaking capacity
1000 W, 4.3 A, at cos phi = 1
Radio range
up to 20 m
Radio frequency
868 MHz
AS-5030_I-Manual_150x180_Fin1.indd 19
20.08.13 14:48
Содержание AS-5030
Страница 11: ...DEUTSCH AS 5030 11 AS 5030_I Manual_150x180_Fin1 indd 11 20 08 13 14 48 ...
Страница 13: ...ENGLISH AS 5030 13 12 11 13 14 15 H 8 9 16 10 TRANSMITTER AS 5030_I Manual_150x180_Fin1 indd 13 20 08 13 14 48 ...
Страница 21: ...AS 5030_I Manual_150x180_Fin1 indd 21 20 08 13 14 48 ...
Страница 23: ...FRANÇAIS AS 5030 23 12 11 13 14 15 H 8 9 16 10 ÉMETTEUR B AS 5030_I Manual_150x180_Fin1 indd 23 20 08 13 14 48 ...
Страница 33: ...NEDERLANDS AS 5030 33 12 11 13 14 15 H 8 9 16 10 ZENDER B AS 5030_I Manual_150x180_Fin1 indd 33 20 08 13 14 48 ...
Страница 42: ...AS 5030_I Manual_150x180_Fin1 indd 42 20 08 13 14 48 ...
Страница 43: ...AS 5030_I Manual_150x180_Fin1 indd 43 20 08 13 14 48 ...