AS-5030 | ENGLISH
14
receiver turns off the connected extractor hood. To turn it
on, open the window(s) with the window contact switch.
After the exhaust pipe is cooled to below 38°C again, the
extractor hood can be used again without a window being
opened.
CAUTION!
The shutters must be open when the extractor hood is in
operation! If the shutters are closed, a sufficient fresh air
supply cannot be guaranteed!
Key
1 =Receiver
2 =Power LED
3 =Window contact LED
4 =Thermal sensor LED
5 =Test button
6 =Window contact
6.1 =Window contact transmitter LED
7 =Magnet
8 =Transmitter module for the thermal sensor
9 =Thermal sensor transmitter LED
10 =Battery compartment
11 =Programming button
12 =Connection terminal for the thermal sensor
13 =Thermal sensor
14 =Exhaust gas pipe
15 =Through hole (4 mm)
16 =Mounting holes (2 mm)
H =Mounting bracket
U =Washers
S =Tamper-proof plug guard
(safeguard against unplugging this device)
WIRELESS EXHAUST AIR CONTROL SYSTEM
MODEL AS-5030
General
Please read these instructions carefully before installing and
operating the device to avoid installation or operating errors.
The wireless exhaust air control system AS-5030 is used in
conjunction with exhaust air systems, such as an extractor
hood in rooms with access to an open fire, for example with
a gas-fuelled heater, an open fireplace, tiled stove, wood-
burning stove, oil-burning stove etc.
When operating an exhaust air system, e.g. an extractor
hood or exhaust fan, air is transported out of the room to
the outside, which can cause negative pressure to form in
the closed space.
The combustion of fuel in an open hearth creates odourless
and invisible carbon dioxide and carbon monoxide gases.
These gases can be sucked into the room from the hearth by
way of an exhaust air system and lead to the fatal poisoning
of anyone spending time in the room.
How the system works
Provided that the stove/exhaust pipe is cold (below 38°C),
the extractor hood connected to the receiver is supplied with
power and functions as usual. If the temperature inside the
exhaust pipe increases to a temperature above 38°C, the
AS-5030_I-Manual_150x180_Fin1.indd 14
20.08.13 14:48
Содержание AS-5030
Страница 11: ...DEUTSCH AS 5030 11 AS 5030_I Manual_150x180_Fin1 indd 11 20 08 13 14 48 ...
Страница 13: ...ENGLISH AS 5030 13 12 11 13 14 15 H 8 9 16 10 TRANSMITTER AS 5030_I Manual_150x180_Fin1 indd 13 20 08 13 14 48 ...
Страница 21: ...AS 5030_I Manual_150x180_Fin1 indd 21 20 08 13 14 48 ...
Страница 23: ...FRANÇAIS AS 5030 23 12 11 13 14 15 H 8 9 16 10 ÉMETTEUR B AS 5030_I Manual_150x180_Fin1 indd 23 20 08 13 14 48 ...
Страница 33: ...NEDERLANDS AS 5030 33 12 11 13 14 15 H 8 9 16 10 ZENDER B AS 5030_I Manual_150x180_Fin1 indd 33 20 08 13 14 48 ...
Страница 42: ...AS 5030_I Manual_150x180_Fin1 indd 42 20 08 13 14 48 ...
Страница 43: ...AS 5030_I Manual_150x180_Fin1 indd 43 20 08 13 14 48 ...