To avoid electric shock, never touch the inside of this apparatus. Only a qualified technician 
should open this apparatus. 

 

Do not drop or strike the product. If the product is damaged, contact a Prostat Authorized Service 
Center. 

 

This equipment is intended for use in electrostatic processes that are free from water, oil, solvent 
and other conductive contaminants.  Exposure  to  such  contaminants  will  cause failure of the 
electrical insulation system in the product 

 

This equipment may require proper grounding for accurate measurement in certain ranges. 

 

This equipment may get damaged if dropped.  In  such  an  event,  it  should  be  carefully  
examined  and  any  necessary  repairs  be  made  by  an  authorized  technician.   

 

Do not exert any pressure on the LCD display from the top. 

 

In rare cases cleaning the PDS-510, case and display with a slightly dampened cloth may be 
required. Should this be required, use a very weak solution on of liquid soap and water. The cloth 
should be barely damp. DO NOT allow the instrument to become wet with the cleaning solution. 

 

DO NOT allow cleaning solution to enter the unit through apparatus openings. Should the unit 
become damaged with cleaning solutions, the warranty is voided. 

 

Do not expose this apparatus to dripping or splashing. 

 

Do not dispose of batteries in a fire. 

 

Do not short-circuit, disassemble, or overheat the batteries. 

 
The system and meter complies with: 
 

Document 

PBT-531 

PDS-510 

ANSI/ESD STM11.31 Shielded Bags 

 

 

 

IEC 61340-4-8 Shielded Bags 

 

 

 

MIL-PRF-81705E Packaging 

 

 

 

ANSI/ESDA/JEDEC JS-001 Human Body Model 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PBT-531

Страница 1: ...USER MANUAL SHIELDED BAG TEST KIT AND POWER SUPPLY PBT 531 PDS 510...

Страница 2: ......

Страница 3: ...mportant Safety Information 2 INTRODUCTION 4 ASSEMBLY INSTRUCTIONS 6 PRE TEST SETUP 7 SYSTEM VERIFICATION TEST 8 Software Setup 8 SHIELDED BAG TESTING 11 PDS 510 POWER SUPPLY 15 CHARGING THE BATTERY 1...

Страница 4: ...ymbol indicates earth ground This symbol represents capacitance This symbol indicates battery safety approval Conforms to European Union directives This product contains a Lithium ion battery that suc...

Страница 5: ...be made by an authorized technician Do not exert any pressure on the LCD display from the top In rare cases cleaning the PDS 510 case and display with a slightly dampened cloth may be required Should...

Страница 6: ...supply that can be used to charge conductive and dissipative materials WARNING As with any electrical device use proper electrical precautions to avoid personnel shock Operating discharge simulators s...

Страница 7: ...is a list of the items included with your product Part No Description PBT 531 PDS 510 PDS 510 HBM Discharge Simulator PBF 520 Shielding Bag Test Fixture CT1 Tektronix CT1 Current Probe PicoScope Osci...

Страница 8: ...6 02 ASSEMBLY INSTRUCTION FOR THE PBF 520 Assembly Base Assembly Base Extension Discharge Arm Capacitive Arm Bracket 1 2 3 4 5 A B C D E...

Страница 9: ...he Base Assembly A of the PBF 520 fixture Figure 1 Connect the 510 054 red lead to the HBM Figure 2 Connect the other end of the 510 054 lead to the Output connector on the PDS 510 Discharge Arm Conne...

Страница 10: ...TEST Software Setup 1 Install the PicoScope software onto the computer by downloading it from Pico s website at https www picotech com downloads Use the version that is closest to the model of your P...

Страница 11: ...000 volts 10 In the PicoScope software if needed move the yellow trigger icon above the scope s zero line 0 2A on the left vertical scale Figure 7 11 Ensure that the scope horizontal scale is set to...

Страница 12: ...lated energy should be 50 6 uJ microjoules and the peak current should be greater than 420 mA milliamps 0 42 amps The blue line is the discharge waveform and the red line is the calculated energy curv...

Страница 13: ...Open and select the Shielding Bag Test File or Shielding Bag Test File with Manual Cursors file from the desktop NOTE If you wish the software to analyze the test automatically use the Shielding Bag T...

Страница 14: ...p of it lines up with the mark on the Capacitive Arm Figure 11 Figure 10 The Capacitive Arm inside the shielded bag Figure 11 The end mark on the Capacitive Arm represents 10 cm 4 from the top of the...

Страница 15: ...utton at the bottom left hand portion of the screen to place the scope in acquisition mode The wording Stopped will change to Running Figure 7 10 Initiate a discharge by pressing the red DISCHARGE but...

Страница 16: ...e calculated energy 13 Repeat the process five more times for a total of six discharges per bag 14 Repeat the test for five more bags 15 ANSI ESD S11 31 requires that the discharge energy for static s...

Страница 17: ...teries to charge make sure the Main Power switch is ON The batteries will not charge if the Main Power is OFF The charger comes with several adapters for different outlets 08 TROUBLESHOOTING PicoScope...

Страница 18: ...or 3 5 or later by going to the Add Remove Programs window in Control Panel and verifying which one is installed 9 Ensure all the latest Windows updates have been applied to the PC 10 Is the PC conne...

Страница 19: ......

Страница 20: ...e owners Complying with all applicable copyright laws is the responsibility of the user Modification of this document is not permitted without written permission from Prostat Corporation Content subje...

Отзывы: