Prostat PBT-531 Скачать руководство пользователя страница 17

15

 

 

06  PDS-510 POWER SUPPLY 

 
The PDS-510 is also equipped with a power supply that can be used to charge UNGROUNDED items 
from 0 to 4,000 volts. In order to use the power supply:  
 

1.

 

Make sure that the PDS-510 is connected to AC ground using one of the unit’s grounding 
ports. 

 

2.

 

Connect a cable to the Power Supply output port of the PDS-510. 

 

3.

 

Adjust the power supply’s voltage to the desired level. 

 

4.

 

Using the open end of the cable contact the cable to the item that requires charging. 

 

5.

 

After charging the item of interest, turn the PDS-510 off to prevent shocks and damage to the 
PDS-510. Care must be exercised to prevent shocks to personnel. 

 
 

07  CHARGING THE BATTERY 

 
The PDS-510 is supplied with a universal charger in order to charge the battery. In order for the 
batteries to charge, make sure the Main Power switch is ON. The batteries will not charge if the Main 
Power is OFF. 
 
The charger comes with several adapters for different outlets. 
 

08  TROUBLESHOOTING 
 

PicoScope 6 does not recognize my device: 
 

1.

 

Verify that the LED light is lit on the front of the oscilloscope. There should be a red light. 

2.

 

Check the USB cable (ensure it is the supplied Pico blue USB cable). Try a different USB port. 

3.

 

If using a device with an external power supply, disconnect and reconnect the power supply. 

4.

 

If using a desktop PC, consider using the rear USB ports. 

5.

 

If using multiple USB devices on a PC and the PicoScope does not have an external power 
supply, consider using a powered USB hub. 

6.

 

Device Manager – confirm that the device is listed either under Pico Technology Instruments 
(or Universal Serial Bus controllers for older models such as the PicoScope 2205). 

7.

 

Confirm that the operating system is Windows XP (SP 3), Vista, 7, 8, 10 or 11 (32 or 64-bit). 

Содержание PBT-531

Страница 1: ...USER MANUAL SHIELDED BAG TEST KIT AND POWER SUPPLY PBT 531 PDS 510...

Страница 2: ......

Страница 3: ...mportant Safety Information 2 INTRODUCTION 4 ASSEMBLY INSTRUCTIONS 6 PRE TEST SETUP 7 SYSTEM VERIFICATION TEST 8 Software Setup 8 SHIELDED BAG TESTING 11 PDS 510 POWER SUPPLY 15 CHARGING THE BATTERY 1...

Страница 4: ...ymbol indicates earth ground This symbol represents capacitance This symbol indicates battery safety approval Conforms to European Union directives This product contains a Lithium ion battery that suc...

Страница 5: ...be made by an authorized technician Do not exert any pressure on the LCD display from the top In rare cases cleaning the PDS 510 case and display with a slightly dampened cloth may be required Should...

Страница 6: ...supply that can be used to charge conductive and dissipative materials WARNING As with any electrical device use proper electrical precautions to avoid personnel shock Operating discharge simulators s...

Страница 7: ...is a list of the items included with your product Part No Description PBT 531 PDS 510 PDS 510 HBM Discharge Simulator PBF 520 Shielding Bag Test Fixture CT1 Tektronix CT1 Current Probe PicoScope Osci...

Страница 8: ...6 02 ASSEMBLY INSTRUCTION FOR THE PBF 520 Assembly Base Assembly Base Extension Discharge Arm Capacitive Arm Bracket 1 2 3 4 5 A B C D E...

Страница 9: ...he Base Assembly A of the PBF 520 fixture Figure 1 Connect the 510 054 red lead to the HBM Figure 2 Connect the other end of the 510 054 lead to the Output connector on the PDS 510 Discharge Arm Conne...

Страница 10: ...TEST Software Setup 1 Install the PicoScope software onto the computer by downloading it from Pico s website at https www picotech com downloads Use the version that is closest to the model of your P...

Страница 11: ...000 volts 10 In the PicoScope software if needed move the yellow trigger icon above the scope s zero line 0 2A on the left vertical scale Figure 7 11 Ensure that the scope horizontal scale is set to...

Страница 12: ...lated energy should be 50 6 uJ microjoules and the peak current should be greater than 420 mA milliamps 0 42 amps The blue line is the discharge waveform and the red line is the calculated energy curv...

Страница 13: ...Open and select the Shielding Bag Test File or Shielding Bag Test File with Manual Cursors file from the desktop NOTE If you wish the software to analyze the test automatically use the Shielding Bag T...

Страница 14: ...p of it lines up with the mark on the Capacitive Arm Figure 11 Figure 10 The Capacitive Arm inside the shielded bag Figure 11 The end mark on the Capacitive Arm represents 10 cm 4 from the top of the...

Страница 15: ...utton at the bottom left hand portion of the screen to place the scope in acquisition mode The wording Stopped will change to Running Figure 7 10 Initiate a discharge by pressing the red DISCHARGE but...

Страница 16: ...e calculated energy 13 Repeat the process five more times for a total of six discharges per bag 14 Repeat the test for five more bags 15 ANSI ESD S11 31 requires that the discharge energy for static s...

Страница 17: ...teries to charge make sure the Main Power switch is ON The batteries will not charge if the Main Power is OFF The charger comes with several adapters for different outlets 08 TROUBLESHOOTING PicoScope...

Страница 18: ...or 3 5 or later by going to the Add Remove Programs window in Control Panel and verifying which one is installed 9 Ensure all the latest Windows updates have been applied to the PC 10 Is the PC conne...

Страница 19: ......

Страница 20: ...e owners Complying with all applicable copyright laws is the responsibility of the user Modification of this document is not permitted without written permission from Prostat Corporation Content subje...

Отзывы: