Configure the MNET Client Module
6201-WA-MNET
♦
ProLinx Wireless
High Speed Wireless Modbus TCP/IP Gateway
ProSoft Technology, Inc.
Page 15 of 48
June 27, 2007
3.1.2 Radio
Configuration
(Client)
Expand the Wireless Configuration section
and double-click on the
icon.
The default Signal LED 1 through 4 parameter values are fixed and cannot be
modified. If you need to change the values for the remaining parameters in this
dialog box, make sure to save your changes before moving on to the next step.
As you select each parameter, the help text area in the lower right area of the
dialog box displays information to help you make your selections.
RTS Threshold
60 to 2347
RTS/CTS handshake threshold byte count in milliseconds. Less than 60 will
interfere with control packets.
Transmit Rate
This parameter defines the data rate(s) for transmission of directed messages.
Possible values are outlined in the following table.
Value Definition
1
Fixed 1 Mbit (1)
2
Fixed 2 Mbit (2)
3
Auto fallback high (11, 5.5, 2, 1)