6.4.3 Synchronizing the IP Settings from the Processor to the MVI69E-MBS
This section covers the process to send the IP settings from the processor to the
MVI69E-MBS.
1
Populate the IP settings in the
MVI69EMBSEthernet.Config
tag:
2
Set the
MVI69EMBSEthernet.Write
bit to
‘
1
’ to trigger the IP settings write operation.
3
The
MVI69EMBSEthernet.Write
bit will automatically reset
to ‘
0
’ once the operation
is concluded.