PUV-3600HD / PUV-4000HD
SECTION 5
5.22
The switch with the solenoid valve power lead and the connecting cable of clearance lights
should be disconnected from the machine and protected against adverse weather conditions.
5.9
TIGHTENING TORQUE FOR NUT AND BOLT
CONNECTIONS
ATTENTION
Should it be necessary to change individual parts, use only original parts or those
indicated by the Manufacturer. Non-adherence to these requirements may put the user
and other people's health and life at risk, and also cause damage to the machine.
TABLE 5.18
TIGHTENING TORQUE FOR NUT AND BOLT CONNECTIONS
5.8
8.8
10.9
THREAD
DIAMETER
[mm]
TIGHTENING TORQUE [Nm]
M6
8
10
15
M8
18
25
36
M10
37
49
72
M12
64
85
125
M14
100
135
200
M16
160
210
310
M20
300
425
610
M24
530
730
1 050
M27
820
1 150
1 650
During maintenance and repairs use appropriate torque for bolt connections (unless other is
specified for a particular connection). Recommended tightening torque values apply to non-
greased steel bolts TABLE 5.18
Содержание PUV-3600HD
Страница 2: ......
Страница 3: ...SNOW PLOUGH PRONAR PUV 3600HD PRONAR PUV 4000HD MACHINE IDENTIFICATION TYPE SERIAL NUMBER ...
Страница 6: ......
Страница 9: ...SECTION 1 BASIC INFORMATION ...
Страница 19: ...SECTION 2 SAFETY ADVICE ...
Страница 29: ...SECTION 3 DESIGN AND OPERATION ...
Страница 38: ...PUV 3600HD PUV 4000HD SECTION 3 3 10 ...
Страница 39: ...SECTION 4 CORRECT USE ...
Страница 58: ...PUV 3600HD PUV 4000HD SECTION 4 4 20 ...
Страница 59: ...SECTION 5 MAINTENANCE ...
Страница 82: ...PUV 3600HD PUV 4000HD SECTION 5 5 24 ...
Страница 83: ...NOTES ...