Promix-SM104

 

 

6

 

See  operating  voltage  range  in  5.2.  Avoid  application  of  a  higher  voltage  or 
excessive pulse duration.

 

Example of lock mounting on a metal cabinet with a swing door.

 

 

 

 

6.2 

CONNECTING PROCEDURE 

The lock operation is controlled by means of energizing and de-energizing. For this purpose, a 

controller  (control  board)  or  a  switch  (button)  is  generally  used.  The  controller  is  mounted  in 
accordance with its certificate. 

Connect the lock power wires adhering to the following polarity: 

Red (black with a red stripe) 

– positive pole of the power supply; 

Black 

– negative pole of the power supply; 

Application of voltage of reverse polarity does not provide the lock operability but does cause 

its failure.  

Connect sensor leads: 

Colored wires (yellow, green, etc.) 

– door position sensor output. 

Example of the lock connection to the remote control system Promix-RDS. 

 

Lock 

Door 

Door 

Lock 

Cable 

channel 

Door 

Lock 

Cable channel 

Lock 

 

Controller Promix-CR.RX 

 

Remote control 

Promix-CR.TX 

 

~220 V 

 

Содержание Promix-SM104 Series

Страница 1: ...s code panels or other devices The lock makes it possible to eliminate mounting a handle on the door since as the lock is opened the door opens slightly by itself 2 LABELING The label stuck to the lock body contains the following information 1 Lock model 2 Patent number 3 Nominal supply voltage 4 Nominal consumed current 5 Date of manufacture and QCD mark 6 Identification number 7 Manufacturer s w...

Страница 2: ...net mounted on the mobile sleeve of the lock and displaced by the latch The reed relay contacts open when the door is opened the latch is withdrawn from the lock and close when the door is closed the latch is inserted into the lock to a stop The sensor is on the back side of the lock 5 TECHNICAL DATA 5 1 OPERATING CONDITIONS The lock operation environment must be explosion safe free of current con...

Страница 3: ... not more than kg 1 5 DC supply voltage U V 12 2 24 2 Current consumed А 0 35 at 12V 0 22 at 24V Supply pulse duration not more than s 0 5 3 Minimum pause between pulses s 15 Built in sensors door position sensor Maximum switch current of the sensor DC А 0 5 Maximum switch voltage of the sensor DC V 36 Sensor output signal type dry contact Lock weight not more than kg 0 15 Holding force not less t...

Страница 4: ...ing of the lock on a swing door Mount the lock on an immobile surface The distance between the inner surface of the closed door to the lock nut must be 10 11 mm which guarantees the necessary free movement of the door within 3 4 mm with the lock closed Connect the lock in accordance with 6 2 1 Sensor fastening place ...

Страница 5: ...e latch is pushed out of the lock De energize the lock Remove the protective film from the two sided adhesive tape on the latch plate and snap the latch into the lock Close the door and press it tightly to the cabinet Energize the lock The door must become slightly open Fasten the latch to the door with self tapping screws Remove the alignment piece The lock is ready for operation 2 3 4 ...

Страница 6: ...ed in accordance with its certificate Connect the lock power wires adhering to the following polarity Red black with a red stripe positive pole of the power supply Black negative pole of the power supply Application of voltage of reverse polarity does not provide the lock operability but does cause its failure Connect sensor leads Colored wires yellow green etc door position sensor output Example ...

Страница 7: ...nment within the latch free movement allowance 3 When the door is closed the latch must be inserted in the lock to stop The lock may fail to open when the door is an excessive tension condition i e an excessive external force for opening is applied see 5 2 4 The properly mounted lock provides the necessary free motion play of the door of 3 4 mm If the free play distance is shorter the lock may fai...

Страница 8: ...gainst the inside of the lock The lock does not fix the latch the door is not closed Check polarity and conformity of the lock supply voltage to the required one Check the distance between the latch and the lock if necessary increase the latch bar length To do this fix the latch support with a wrench loosen the latch nut screw out the bar tighten the latch nut The door has sunk during use automati...

Страница 9: ... correspond to class III as per ГОСТ 12 2 007 0 75 and are electrically safe Fire safety of the locks is ensured by use of non combustible or hardly combustible materials and low supply voltage 12 DISPOSAL The product is not hazardous for human life and health or for the environment disposal after its service life is performed without taking any special measures for environment protection 13 WARRA...

Страница 10: ... and accepted in compliance with Specifications ПШБА 304268 001 ТУ obligatory requirements of state standards and current technical documentation recognized as fit for operation and packed by ETC PROMIX LLC PROMIX Engineering and Technical Center LLC Russia 214030 Smolensk Krasninskoye sh 35 lit A Phone 4812 619 330 www promix center ru vk com promixcenter facebook com promixcenter mail promix cen...

Отзывы: