FastTrak TX4310 User Manual
2
Product Overview
The PC which you are using either already contains a FastTrak TX4310 RAID
Controller card installed by a third-party or you have acquired a FastTrak TX4310
retail product for your existing PC and plan to install the card yourself.
•
For PC owners wishing to install their TX4310 RAID, go to “Chapter 2:
Installation” on page 7.
•
For PCs with a FastTrak TX4310 already installed, and you are experiencing
any difficulties with the disk drives being recognized by the card, go to
“Chapter 7: Support” on page 109.
•
If your operating system has crashed for some reason or you have
downloaded updated drivers from the Promise website (www.promise.com),
you may wish to reinstall software drivers for the FastTrak TX4310. See
“Chapter 3: Install Drivers” on page 23.
FastTrak TX 4310
Promise originally designed the FastTrak TX4310 RAID Controller card as a cost-
effective, high performance RAID controller card that adds performance and
reliability to PC desktops and servers using Serial ATA drives. FastTrak TX4310
has four independent data channels to support a maximum of four Serial ATA
drives and supports:
•
Stripe (RAID 0) – Identical drives can read and write data in parallel to
increase performance.
•
Mirror (RAID 1) – Mirror increases read performance through load balancing
and elevator sorting while creating a complete backup of your files.
•
Stripe with Parity (RAID 5) – Combines data striping to increase performance
with parity data to provide fault tolerance.
•
Mirror / Stripe (RAID 10) – Combining mirror with stripe offers both high read/
write performance and fault tolerance
A FastTrak TX4310 striped disk array can double the sustained data transfer rate
of Serial ATA drives.
FastTrak TX4310 offers fault tolerant, data redundancy for entry-level network file
servers or simply for desktop PC users wanting to continually protect valuable
data on their PC.
Should a drive that is part of a mirrored or parity disk array fail, FastTrak TX4310
uses the mirrored drive or the parity to assume all data handling. When a new
replacement drive is later installed, FastTrak TX4310 rebuilds data to the new
drive from the mirrored driveor parity to restore fault tolerance.
Содержание FastTrak TX4310
Страница 1: ...FASTTRAK TX4310 USER MANUAL Version 1 1 ...
Страница 4: ...FastTrak TX4310 User Manual iv ...
Страница 14: ...FastTrak TX4310 User Manual 6 ...
Страница 30: ...FastTrak TX4310 User Manual 22 ...
Страница 50: ...FastTrak TX4310 User Manual 42 ...
Страница 102: ...FastTrak TX4310 User Manual 94 ...
Страница 116: ...FastTrak TX4310 User Manual 108 ...