6
Assembly
–
Compare the dimensions on the dimension sheet with
those of the pump.
1.
Select a suitable motor - it must correspond to the data of one of the
motors from the table "Motor data" - see Chapter "Technical data"
WARNING!
In an area at risk from explosion, EX applies to
selected equipment and methods!
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the clutch operating instructions!
WARNING!
In an area at risk from explosion, EX applies to
selected equipment and methods!
With a dog clutch: The claw on the motor shaft must be fixed at the
‘Motor installation - for versions without a
3.
As you have converted an "incomplete machine" into a complete
machine, you must perform a conformity assessment, risk assess‐
ment, create an EC Declaration of Conformity, fit a company name‐
plate, ... .For ATEX pumps: additionally perform an ignition hazard
assessment
4.
Complete the pump documentation / operating instructions.
Motor installation - for versions without a
motor
Assembly
20