n
Never operate pumps in premises at risk from explosion without the
relevant nameplate (and the respective EC Declaration of Conformity)
for pumps for use in premises at risk from explosion.
n
The pump is not intended for the metering of gaseous media and
solids.
n
The pump is not intended for the metering of explosive substances
and explosive mixtures.
n
The ATEX version is not intended for the metering of electrically non-
conductive media (conductivity less than 50 pS/m).
n
Do not expose the ATEX design to any ionising radiation, electromag‐
netic high frequency radiation in the range 10
4
... 3x10
15
Hz or ultra‐
sound without putting in place measures in line with EN 1127-1.
n
The pump is not intended for unprotected outside use.
n
The pump is only intended for industrial use.
n
The pump should only be operated by trained and authorised per‐
sonnel, see the following table.
n
You are obliged to observe the information contained in the operating
instructions at the different phases of the unit's service life.
n
You are obliged to observe the information contained in the operating
instructions of the accessory devices at the different phases of their
respective service lives.
Task
Qualification
Storage, transport, unpacking
Instructed person
Assembly
Technical personnel, service
Planning the hydraulic installation
Qualified personnel who have a
thorough knowledge of metering
pumps
In areas at risk from explosion:
ATEX qualified person, ATEX elec‐
trical technician
Hydraulic Installation
Technical personnel, service
Installation, electrical
Electrical technician,
In areas at risk from explosion:
ATEX electrical technician
Start up
Qualified personnel
In areas at risk from explosion:
Qualified personnel with ATEX
training; checking of the electrical
installation: recognised competent
person
Operation
Instructed person
Maintenance, repair
Technical personnel, service
In areas at risk from explosion:
ATEX qualified person, ATEX elec‐
trical technician
Decommissioning, disposal
Technical personnel, service
Troubleshooting
Qualified person, electrical techni‐
cian, instructed person, customer
service - dependent on the require‐
ment
In areas at risk from explosion:
ATEX electrical technician;
checking of the electrical installa‐
tion: recognised competent person
Qualification of personnel