Interval
Inspection point
Re-tighten the threaded joint (tightening torque: 5 Nm).
Check whether the external bearings are still firmly screwed to the stator without gaps (tight‐
ening torque: 6 Nm).
Check that there are no thick layers of dust on the motor housing and external bearings.
Heavy layers of dust interfere with heat radiation.
If friction is noticeable when the rotor is running, immediately stop the motor. The alignment
of the load guide and the rotor must be checked - see operating instructions for the motor.
7.2 Maintenance work
Interval
Maintenance work (pump is not in operation and cooled to room temperature).
annually
Chapter 7.3 ‘Changing the hydraulic oil’ on page 41
.
Clean the pump. *
Chapter 7.5 ‘Replacing the diaphragm’ on page 44
26,000 operating hours or a max‐
imum of 5 years
A complete factory overhaul is recommended.
* In areas at risk from explosion, only clean the pump outside of explosive atmospheres.
Case-specific
Maintenance work (pump is not in operation and cooled to room temperature).
Overpressure
Immediately check the pressure relief valve and the seals of the liquid end and
replace if necessary.
Maintenance
40
Содержание EMFa
Страница 67: ...11 14 Motor data Technical data 67...
Страница 68: ...Technical data 68...