Page 11
Dulcodes UV-Desinfektionsanlage
4.3.2
Changing Enable Code
To prevent unauthorised changes to the settings, the system control has an enable code for
programming mode. This code can be freely selected by the operator.
Programming mode is still disabled after changing the enable code. The disable is cancelled only
after entering the new enable code.
IMPORTANT!
Note down the enable code! Parameters can be set only after entering the correct enable
code.
The default enable code does not provide protection against unauthorised changes.
Default
5000
4.3.3
Setting Language
It is possible to choose between various languages:
German, English, French, Spanish
Default
German
4.3.4
Activating/Deactivating Ballast Bus
The ballasts for the high-flux lamps (e.g. 80 W lamps, 130 W lamps, 230 W lamps) are equipped
with a bus interface. The UV lamps are ignited and switched off and their operation monitored via
this bus interface. The lamp current can also be varied.
With the system switched on, the number of ballasts can be indicated when the bus is active.
The serial number of the individual ballasts can be checked with the UP and DOWN keys.
IMPORTANT!
The bus must be switched to active in UV disinfection systems that feature ballasts with a
bus interface. The lamps cannot be ignited when the bus is set to passive.
Default
Active for systems equipped with ballasts with a bus interface otherwise passive.
Control
Bus active
10 lamps
EVG#001
EVG identifier
Bus passive
Language
German
New
enable code
xxxx
Memory display
1 sec
(Enable code query)
Changes are stored
Enable code
confirmation
xxxx
Incorrect enable
code
Changes are not stored
C
Return to query
“Change
enable code”
BA_DS_009_10_06_GB.p65
20.10.2006, 7:31 Uhr
11