Page 22
Dulcodes UV-Desinfektionsanlage
5
4
ATTENTION!
Use the appropriate tools to break out the blanked off cable leadthroughs on the underside
of the control unit so as no to damage the pc-board and the thread.
Break out blanked-off cable leadthroughs on the underside of the control unit
First install the cables in the rear row:
Fit screwed gland, thrust collar and seal from supplied supplementary kit on the cable, screw
into the threaded hole and tighten by hand
Pull PG-7 screwed glands over the cable and lock with lock nut
Route strands to the terminals corresponding to the terminal connection diagram
Connect unused terminals to the corresponding plug connectors
Close control unit
Assembly and Installation
3
2
1
Fig. 3: Opening control unit
Fig. 4: Cable leadthrough – rear row
1 PG-11 screwed gland
2 Metal ring
3 Rubber seal
Fig. 5: Cable leadthrough – front row
4 PG-7 screwed gland
5 Lock nut
5
4
BA_DS_009_10_06_GB.p65
20.10.2006, 7:31 Uhr
22