11
Technical data
11.1 Specifications of the Chlorinsitu
®
IIa 625 ... 2500 g/h
Capacity (FAC production)
All technical data applies to an
ambient temperature of 20 °C and a
water temperature of 15 °C
625 g/h
15 kg/day
1250 g/h
30 kg/day
2500 g/h
60 kg/day
System availability
24 h/day
Salt turnover
3.0 kg/kg FAC
Energy consumption DC
4.0 kWh/kg FAC
FAC concentration*, based on NaCl
as the starting substance
9 g/l ± 10 % (0.9 % ± 10 %)
pH value of product (approx.)
9.5
Number of electrolysis cells
1
2
1
Product volume (NaOCI)
75 l/h
1800 l/day
150 l/h
3600 l/day
300 l/h
490 l/day
Chlorate
< 4 % based on freely available chlorine
Power supply
3 x 400/230 VAC ± 10 %, neutral, 50 Hz
Nominal energy consumption
3.8 kW
6.8 kW
12.8 kW
External installation fuse
3x25 male
3x40 male
Salt consumption
1.8 kg/h
45 kg/day
3.75 kg/h
90 kg/day
7.5 kg/h
180 kg/day
Salt quality requirements
CHLORINSITU
®
salt or salt tablets that meet the following specifica‐
tions:
min. 99.4 % NaCl,
max. 0.05 % insoluble substances,
max. 10 mg/kg iron,
max. 10 mg/kg manganese,
max. 100 mg/kg c magnesium
Max. relative humidity
85 %
Ambient temperature
10 ... 40 °C
(no direct sunlight)
Inlet water temperature
15 ... 25 °C, higher/lower temperatures require a chiller/heater.
Inlet water specification
Potable water quality / > 2 ... < 5 bar / > 32 l/min / Water feed max.
30 °dH
Ambient conditions
The air in the installation room must be non-condensing, non-corro‐
sive and free of dust.
External salt dissolving tank
200 l
380 l
520 l
Disinfection applications
Swimming pools cooling towers, potable water, process water etc.
All specifications are stated at an ambient temperature of 20 °C and a water temperature of 15 °C.
* The output of the system is affected by the temperature and the quality of the water and salt.
Technical data
40