1.1 Sigma 1
1.1.1 Performance data – Sigma 1
Type
Minimum pump capacity at maximum
back pressure
Maximum
stroke rate
Priming lift
Suction lift
Connector
size
bar
l/h
ml/stroke
Strokes/min
mbar
mbar
DN
10022
10
24
5.5
73
200
500
10
10044
10
46
5.3
143
200
500
10
07065
7
68
5.5
205
200
500
10
Type
Minimum pump capacity at maximum back pressure
Maximum
stroke
rate
Priming
lift
Suction
lift
Con‐
nector
size
bar
psi
l/h
gph
ml/stroke Strokes/m
in
mbar
mbar
DN
10022
10
145
29
7.6
4.7
88
200
500
10
10044
10
145
55
21.4
4.5
172
200
500
10
07042
7
102
81.1
21.4
8.7
88
200
500
15
Type
Minimum pump capacity at maximum
back pressure
Maximum
stroke rate
Priming lift
Suction lift
Connector
size
bar
l/h
ml/stroke
Strokes/min
mbar
mbar
DN
10022
10
30
4.7
88
200
500
10
10044
10
54
4.5
172
200
500
10
07065
7
66
4.7
200
200
500
10
All figures are guideline figures for water at 20 °C.
The priming lift applies to clean, moist valves, an empty suction line and
empty liquid end - with correct installation.