Chapter 5: SPECIFICATIONS
59
April 2018
►
Configuration Menu
►
Downstream
►
Upstream
Parameter
Value
Additional Data
Channel Plan
Yes
Standard TV Channel plans
CCIR,EIA,HRC,IRC,OIRL,FCC up to 10
Customized Channel plan
Up to 30
Units
dBmV, dBuV, dBm
Reference Line
from –60 dBmV to 120 dBmV
Units
dBmV, dBuV, dBm
Reference Line
from –60 dBmV to 120 dBmV
Thresholds
Max and Min limits for quality evalua-
tion
5.3
Tilt
Parameter
Value
Additional Data
Frequency:
Four selectable tuning frequencies
(pilots) from 45 MHz to 1700 MHz
Tuning resolution:
10 kHz
Bandwidth resolution
230 kHz
Dynamic range:
-50 dBmV to 60 dBmV
Screen range:
50 dB
Max Input level:
70 dBmV
Resolution:
0.1 dB
Measurements:
Level of four selected frequencies
±0 to 30 dB/ MHz (Tilt) between two
selected pilots
Resolution:
0.1 dB
Parameter
Value
Additional Data
Frequency:
Four selectable tuning frequencies
(pilots) from 45 MHz to 1700 MHz
Tuning resolution:
10 kHz
Bandwidth resolution
230 kHz
Dynamic range:
-50 dBmV to 60 dBmV
Screen range:
50 dB
Max Input level:
70 dBmV
Resolution:
0.1 dB
Measurements:
Level of four selected frequencies
±0 to 30 dB/ MHz (Tilt) between two
selected pilots
Resolution:
0.1 dB
Содержание CABLE RANGER
Страница 1: ...CABLERANGER FIBER COAXIAL DOCSIS ANALYZER 0 MI2125...
Страница 11: ...April 2018 6 Chapter 2 SETTING UP Figure 3 Front View 2 3 Equipment Details...
Страница 12: ...Chapter 2 SETTING UP 7 April 2018 Figure 4 Side View...
Страница 50: ...Chapter 4 TOOLS 45 April 2018 Create a Channel Plan from an existing one Figure 23...
Страница 52: ...Chapter 4 TOOLS 47 April 2018 Create automatically a channel plan from HFC network Figure 25...