April 2018
22
Chapter 3: MEASUREMENT
13
Arrows to increase / decrease span. Current span.
14
Bandwidth resolution.
15
Selected marker for channel / frequency.
►
Options Menu
There are some options at the bottom of the screen:
: Screenshot.
CLEAR: It clears spectrum trace (this options is available if trace was hold
previously).
DBG: It opens DOCSIS BONDING GROUP screen (see next section).
RANGING (only for CABLE): It enables RANGING function (see next
section).
DEMOD: Demodulator (refer to "Demodulator" chapter).
►
Settings Menu
Click on the
MENU icon at the upper right corner to access the Settings
menu. The DOCSIS DOWNSTREAM SPECTRUM ANALYZER function has
these options:
Edit channel plan: It allows you to edit a channel plan and DBG (refer to
"Edit Channel Plan" chapter).
Units: It allows you to select measurement unit for power (dBuV, dBmV,
dBm).
Reference Line: It allows you to select the reference line by numbers
(-60 dBmV to +70 dBmv). Reference line allows you to define criteria in
order to quickly accept or refuse channels levels.
Trace: It allows you to select holding type of trace (maximal, minimum).
CM information: Information about the cable modem.
Frequency step: It allows you to select frequency step (0.25 MHz, 1
MHz, 8 MHz, other value).
Full span maximum frequency: It allows you to select full span
maximum frequency (900 MHz, 1700 MHz, other value).
Detector: It allows you to select detector type (maximum, minimum).
Wavelenght (only for FO): It allows you to select wavelength (1310
nm, 1490 nm, 1550 nm, 1590 nm).
Содержание CABLE RANGER
Страница 1: ...CABLERANGER FIBER COAXIAL DOCSIS ANALYZER 0 MI2125...
Страница 11: ...April 2018 6 Chapter 2 SETTING UP Figure 3 Front View 2 3 Equipment Details...
Страница 12: ...Chapter 2 SETTING UP 7 April 2018 Figure 4 Side View...
Страница 50: ...Chapter 4 TOOLS 45 April 2018 Create a Channel Plan from an existing one Figure 23...
Страница 52: ...Chapter 4 TOOLS 47 April 2018 Create automatically a channel plan from HFC network Figure 25...