Promate PH1500 Скачать руководство пользователя страница 8

WARNING

CAUTION

DANGER

CAUTION

CAUTION

PRE-START PREPARATION

Before starting the generator, check for loose 

or missing parts and for any damage which 

may have occurred during shipment.

This generator must not be operated without 

all factory installed heat shields in place. 

Failure to comply may cause the fuel tank 

to overheat and result in personal injury 

from fire.

STARTING THE ENGINE

1. Check oil level and fuel.

2. Disconnect all electrical loads from the

unit.

3. Open fuel shut off valve.

4. Adjust choke as necessary.

5. Set the engine switch to the “ON"

position.

6. Pull on the starter rope with fast steady   

pull. As the engine warms up, readjust

the choke. On electric start models,    

turn the key switch to “START”. Release   

key switch after the engine starts.

Allow generator to run at no load for five 

minutes upon each initial start-up to permit 

engine and generator to stabilize.

• Provide adequate ventilation for toxic   

exhaust gases and cooling air flow.

• Do not start or run the generator in   

an enclosed area, even if door or    

windows are open.

• Engines give off carbon monoxide, an   

odorless, colorless, poison gas.

• Breathing carbon monoxide can cause   

nausea, fainting or death.

APPLYING LOAD

This unit has been pretested and adjusted to 

handle its full capacity. When starting the 

generator, disconnect all load. Apply load only 

after generator is running. Voltage is regulated 

via the engine speed adjusted at the factory 

for correct output. Readjusting will void 

warranty.

When applying a load, do not exceed the 

maximum wattage rating of the generator 

when using one or more receptacles. Also, 

do not exceed the amperage

rating of any one receptacle.

CIRCUIT BREAKER

Do not apply heavy electrical load during 

break-in period (the first two to three hours 

of operations).

The receptacles are protected by an AC circuit 

breaker. If the generator is overloaded or an 

external short circuit occurs, the circuit breaker 

will trip. If this occurs, disconnect all electrical 

loads and try to determine the cause of the 

problem before attempting to use the 

generator again. If overloading causes the 

circuit breaker to trip, reduce the load. NOTE: 

Continuous tripping of the circuit breaker may 

cause damage to generator or equipment. 

The circuit breaker may

be reset by switching to the ON position.

SHUTTING THE GENERATOR OFF

1. Remove entire electrical load.

2. Let the engine run for two minutes

without load.

3. Move the engine switch to the “OFF”

position. (Turn the key switch to “OFF”   

on the electric start models).

4. Do not leave the generator until it has

completely stopped.

5. Close the fuel shut off valve if the engine   

is to be put in storage or transported.

6. If a cover is used, do not install until

unit has cooled.

8

Содержание PH1500

Страница 1: ...pment thoroughly read and understand these instructions and any additional instructions provided prior to operation Record the model and serial numbers of your Generator below Model No _________________________________________ Serial No _________________________________________ PH1500 ...

Страница 2: ...PH1500 ...

Страница 3: ... generator clean and free of oil mud and other foreign matter 10 Extension cords power cords and all electrical equipment must be in good condition Never operate electrical equipment with damaged or defective cords 11 Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generator 12 Your generator should never be operated under these conditions ...

Страница 4: ...be caught in the starter or other rotating parts 17 Unit must reach operating speed before electrical loads are connected Disconnect loads before turning off engine 18 To prevent surging that may possibly damage equipment do not allow engine to run out of fuel when electrical loads are applied 19 When powering solid state equipment a Power Line Conditioner should be used to avoid possible damage t...

Страница 5: ... television set is used A power line conditioner is recommended for some solid state applications A power line conditioner should be used when running one or more of the following solid state items Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment Other solid state equipment may require a power line c...

Страница 6: ...ying combustible material as the ground source LUBRICATION DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil Your generator has been shipped from the factory without oil in the crankcase Operating the unit without oil can damage the engine Fill the engine with oil according to the operator manual For units with a dipstick fill oil to the prop...

Страница 7: ... to bring the level back up to the manufacturer s required level WARNING Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in the area while charging Connect the red clip to the position terminal of the battery Connect the black clip to the negative terminal of the battery Insert the DC plug into the DC receptacle ...

Страница 8: ...apacity When starting the generator disconnect all load Apply load only after generator is running Voltage is regulated via the engine speed adjusted at the factory for correct output Readjusting will void warranty When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle CIRCUIT BR...

Страница 9: ... Next set the gap at 028 031 inches 0 7 0 8 mm by adjusting the negative electrode Replace the spark plug with correct torque 14 ft lb 20 N m Replace with only the same type of spark plug which was removed An improper spark plug can cause the engine to overheat emit smoke or otherwise perform poorly OIL TYPE Use new good quality oil SE SF or SD grade The oil to be used depends upon the temperature...

Страница 10: ...IPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE If your unit has been sitting around for a long time period and is hard to start try doing some of these easy steps before calling the Customer Hotline 1 Check the oil level 2 Replace the old fuel 3 Change the spark plug 4 Check the fuel lines Make sure the fuel valve is open 5 Check all generator parts for integrity 6 Clean the Carburetor SERVICE AN...

Страница 11: ...ope sharply No fuel in tank Fuel shut off not open Supply fuel Spark plug dirty with carbon or wet with fuel Remove carbon or wipe spark plug with dry cloth Improper spark Damage spark plug Replace plug Faulty magneto Consult dealer Combustion chamber supplied with fuel Sufficient compression Improper adjustment of carburetor Proper spark Insufficient pulling speed for starting rope Pull rope shar...

Страница 12: ...osion erosion and normal wear and tear Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner s manual or if the product is used as rental equipment The Company will not pay for repairs or adjustments to the product or for any costs or labor performed without the Company s pr...

Страница 13: ...ly Ball bearing 6203 Stator assembly Wire clip Flat washer 5 Spring washer 5 Screw M5 15 Stator cover Rear frame Spring washer 6 Screw M6 105 Alternator center screw Alternator rear cover Nut M8 Screw M8 30 Electrical machinery rack 2 1 1 2 1 1 22 2 2 1 2 4 4 1 1 1 1 1 1 9 1 2 1 4 1 1 1 1 3 3 3 1 1 5 4 1 1 16 2 1 Ref No Part No Description Qty Note 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 5...