GROUND TERMINAL LOCATION:

GROUND TERMINAL

WARNING

CAUTION

system turn off the main switch. Before 

making permanent connections a double 

throw transfer switch must be installed. To 

avoid electrocution or property damage, only 

a trained electrician should connect generator 

to residence electrical system. California 

law requires isolation of the residence 

electrical system before connecting a 

generator to residence electrical systems. 

Temporary connection not recommended 

due to backfeeding.

Always follow local codes and regulations 

that apply to the installation of any item that 

concerns this product.

1. NFPA 70 - National Electrical Code.

2. NFPA 37 - Standard for Installation   

and Use of Stationary Combustible   

Engines.

3. Agricultural Wiring handbook of    

Farm Standby Electric Power.

BEFORE OPERATION

GROUNDING THE GENERATOR

The National Electric Code requires that this 

product be properly connected to an 

appropriate earth ground to help prevent 

electric shock. A ground terminal connected 

to the frame of the generator has been 

provided for this purpose. Connecting a length 

of heavy gauge (12 AWG min.) copper wire 

between the generator Ground Terminal and 

a copper rod driven into the ground should 

provide a suitable ground connection. However, 

consult with a local electrician to insure that 

local codes are being adhered to.

WARNING Do not use a pipe carrying 

combustible material as the ground source. 

LUBRICATION

DO NOT  attempt to start this engine without 

filling the crank case with the proper amount 

and type of oil. Your generator has been 

shipped from the factory without oil in the 

crankcase. Operating the unit without oil can 

damage the engine.

Fill the engine with oil according to the operator 

manual. For units with a dipstick, fill oil to the 

proper level. Units without a dipstick should 

be filled to the top of the opening of the oil fill.

LOW OIL SENSOR

The unit is equipped with a low oil sensor. If 

the oil level becomes lower than required, the 

sensor will activate a warning device or stop 

the engine.

If generator shuts off and the oil level is within 

specifications, check to see if generator is 

sitting at an angle that forces oil to shift. Place 

on an even surface to correct this.

If engine fails to start, the oil level may not be 

sufficient to deactivate low oil level switch. 

Make sure the sump is completely full of oil.

FUEL

Fill the tank with clean, fresh unleaded 

automotive gasoline. Regular grade gasoline 

may be used provided a high octane rating is 

obtained (at least 85 pump octane). We 

recommend always using a fuel stabilizer. A 

fuel stabilizer will minimize the formulation of 

fuel gum deposits during storage. The fuel 

stabilizer can be added to the gasoline in the 

fuel tank, or into the gasoline in a storage 

container.

CAUTION Do not overfill the tank. Keep 

maximum fuel level 

1/4

'bc inch below the 

top of the fuel tank. This will allow expansion 

in hot weather and prevent overflow.

6

Содержание PH1500

Страница 1: ...pment thoroughly read and understand these instructions and any additional instructions provided prior to operation Record the model and serial numbers of your Generator below Model No _________________________________________ Serial No _________________________________________ PH1500 ...

Страница 2: ...PH1500 ...

Страница 3: ... generator clean and free of oil mud and other foreign matter 10 Extension cords power cords and all electrical equipment must be in good condition Never operate electrical equipment with damaged or defective cords 11 Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generator 12 Your generator should never be operated under these conditions ...

Страница 4: ...be caught in the starter or other rotating parts 17 Unit must reach operating speed before electrical loads are connected Disconnect loads before turning off engine 18 To prevent surging that may possibly damage equipment do not allow engine to run out of fuel when electrical loads are applied 19 When powering solid state equipment a Power Line Conditioner should be used to avoid possible damage t...

Страница 5: ... television set is used A power line conditioner is recommended for some solid state applications A power line conditioner should be used when running one or more of the following solid state items Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment Other solid state equipment may require a power line c...

Страница 6: ...ying combustible material as the ground source LUBRICATION DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil Your generator has been shipped from the factory without oil in the crankcase Operating the unit without oil can damage the engine Fill the engine with oil according to the operator manual For units with a dipstick fill oil to the prop...

Страница 7: ... to bring the level back up to the manufacturer s required level WARNING Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in the area while charging Connect the red clip to the position terminal of the battery Connect the black clip to the negative terminal of the battery Insert the DC plug into the DC receptacle ...

Страница 8: ...apacity When starting the generator disconnect all load Apply load only after generator is running Voltage is regulated via the engine speed adjusted at the factory for correct output Readjusting will void warranty When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle CIRCUIT BR...

Страница 9: ... Next set the gap at 028 031 inches 0 7 0 8 mm by adjusting the negative electrode Replace the spark plug with correct torque 14 ft lb 20 N m Replace with only the same type of spark plug which was removed An improper spark plug can cause the engine to overheat emit smoke or otherwise perform poorly OIL TYPE Use new good quality oil SE SF or SD grade The oil to be used depends upon the temperature...

Страница 10: ...IPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE If your unit has been sitting around for a long time period and is hard to start try doing some of these easy steps before calling the Customer Hotline 1 Check the oil level 2 Replace the old fuel 3 Change the spark plug 4 Check the fuel lines Make sure the fuel valve is open 5 Check all generator parts for integrity 6 Clean the Carburetor SERVICE AN...

Страница 11: ...ope sharply No fuel in tank Fuel shut off not open Supply fuel Spark plug dirty with carbon or wet with fuel Remove carbon or wipe spark plug with dry cloth Improper spark Damage spark plug Replace plug Faulty magneto Consult dealer Combustion chamber supplied with fuel Sufficient compression Improper adjustment of carburetor Proper spark Insufficient pulling speed for starting rope Pull rope shar...

Страница 12: ...osion erosion and normal wear and tear Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner s manual or if the product is used as rental equipment The Company will not pay for repairs or adjustments to the product or for any costs or labor performed without the Company s pr...

Страница 13: ...ly Ball bearing 6203 Stator assembly Wire clip Flat washer 5 Spring washer 5 Screw M5 15 Stator cover Rear frame Spring washer 6 Screw M6 105 Alternator center screw Alternator rear cover Nut M8 Screw M8 30 Electrical machinery rack 2 1 1 2 1 1 22 2 2 1 2 4 4 1 1 1 1 1 1 9 1 2 1 4 1 1 1 1 3 3 3 1 1 5 4 1 1 16 2 1 Ref No Part No Description Qty Note 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 5...