are open; avoid areas where     

vapors may be trapped, such as

pits, garages, cellars, excavations

and boat bilges.

DANGER - CARBON MONOXIDE

HAZARD: The engine exhaust

contains carbon monoxide, a

poisonous, odorless, invisible gas

which, if breathed, may cause     

death or serious personal injury.    

If you start to feel sick, dizzy or    

weak while using the generator,    

shut it off and get to fresh air     

right away; you may have carbon

monoxide poisoning.

b. Good ventilation for cooling. Air

flow and temperatures are     

important for air cooled units.     

Temperatures should not exceed    

104º'ba F ambient (40º'ba C).

c. Refuel the generator in a well

lighted area. Avoid fuel spills and    

never refuel while the generator

is running. Allow engine to cool for

two minutes prior to refueling.

d. Do not refuel near open flames,

pilot lights, or sparking electrical

equipment such as power tools,

welders, and grinders.

e. The muffler and air cleaner must    

be installed and in good condition

at all times as they function as

flame arresters if backfiring occurs.

f.

Do not smoke near the generator.

15. Ensure that generator is properly

grounded. (See “Grounding the generator”

section in this manual.)

16. Do not wear loose clothing, jewelry, or   

anything that may be caught in the starter  

or other rotating parts.

17. Unit must reach operating speed before

electrical loads are connected. Disconnect

loads before turning off engine.

18. To prevent surging that may possibly   

damage equipment, do not allow engine

to run out of fuel when electrical loads

are applied.

19. When powering solid state equipment,

a Power Line Conditioner should be used

to avoid possible damage to equipment.

20. Do not stick anything through ventilating

slots, even when the generator is not

operating. This can damage the generator

or cause personal injury.

21. Before transporting the generator in a   

vehicle, drain all fuel to prevent leakage

that may occur.

22. Use proper lifting techniques when

transporting the generator from site to  

site. Improper lifting techniques may

result in personal injury.

23. To avoid burns, do not touch engine   

muffler or other engine or generator   

surfaces which became hot during   

operation.

SPARK ARRESTER

YOUR PRODUCT MAY NOT BE EQUIPPED 

WITH A SPARK ARRESTING MUFFLER . If 

the product will be used around flammable 

materials, such as agricultural crops, forests, 

brush, grass, or other similar items, then an 

approved spark arrester should be installed 

and is legally required in the State of California. 

The California statutes requiring a spark 

arrester are Sections 13005(b), 4442 and 

4443. Spark Arresters are also required on 

some U.S. Forest Service land

and may also be legally required under other 

statutes and ordinances.

Содержание PH1500

Страница 1: ...pment thoroughly read and understand these instructions and any additional instructions provided prior to operation Record the model and serial numbers of your Generator below Model No _________________________________________ Serial No _________________________________________ PH1500 ...

Страница 2: ...PH1500 ...

Страница 3: ... generator clean and free of oil mud and other foreign matter 10 Extension cords power cords and all electrical equipment must be in good condition Never operate electrical equipment with damaged or defective cords 11 Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generator 12 Your generator should never be operated under these conditions ...

Страница 4: ...be caught in the starter or other rotating parts 17 Unit must reach operating speed before electrical loads are connected Disconnect loads before turning off engine 18 To prevent surging that may possibly damage equipment do not allow engine to run out of fuel when electrical loads are applied 19 When powering solid state equipment a Power Line Conditioner should be used to avoid possible damage t...

Страница 5: ... television set is used A power line conditioner is recommended for some solid state applications A power line conditioner should be used when running one or more of the following solid state items Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment Other solid state equipment may require a power line c...

Страница 6: ...ying combustible material as the ground source LUBRICATION DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil Your generator has been shipped from the factory without oil in the crankcase Operating the unit without oil can damage the engine Fill the engine with oil according to the operator manual For units with a dipstick fill oil to the prop...

Страница 7: ... to bring the level back up to the manufacturer s required level WARNING Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in the area while charging Connect the red clip to the position terminal of the battery Connect the black clip to the negative terminal of the battery Insert the DC plug into the DC receptacle ...

Страница 8: ...apacity When starting the generator disconnect all load Apply load only after generator is running Voltage is regulated via the engine speed adjusted at the factory for correct output Readjusting will void warranty When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle CIRCUIT BR...

Страница 9: ... Next set the gap at 028 031 inches 0 7 0 8 mm by adjusting the negative electrode Replace the spark plug with correct torque 14 ft lb 20 N m Replace with only the same type of spark plug which was removed An improper spark plug can cause the engine to overheat emit smoke or otherwise perform poorly OIL TYPE Use new good quality oil SE SF or SD grade The oil to be used depends upon the temperature...

Страница 10: ...IPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE If your unit has been sitting around for a long time period and is hard to start try doing some of these easy steps before calling the Customer Hotline 1 Check the oil level 2 Replace the old fuel 3 Change the spark plug 4 Check the fuel lines Make sure the fuel valve is open 5 Check all generator parts for integrity 6 Clean the Carburetor SERVICE AN...

Страница 11: ...ope sharply No fuel in tank Fuel shut off not open Supply fuel Spark plug dirty with carbon or wet with fuel Remove carbon or wipe spark plug with dry cloth Improper spark Damage spark plug Replace plug Faulty magneto Consult dealer Combustion chamber supplied with fuel Sufficient compression Improper adjustment of carburetor Proper spark Insufficient pulling speed for starting rope Pull rope shar...

Страница 12: ...osion erosion and normal wear and tear Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner s manual or if the product is used as rental equipment The Company will not pay for repairs or adjustments to the product or for any costs or labor performed without the Company s pr...

Страница 13: ...ly Ball bearing 6203 Stator assembly Wire clip Flat washer 5 Spring washer 5 Screw M5 15 Stator cover Rear frame Spring washer 6 Screw M6 105 Alternator center screw Alternator rear cover Nut M8 Screw M8 30 Electrical machinery rack 2 1 1 2 1 1 22 2 2 1 2 4 4 1 1 1 1 1 1 9 1 2 1 4 1 1 1 1 3 3 3 1 1 5 4 1 1 16 2 1 Ref No Part No Description Qty Note 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 5...