en

 

The fog from the unit’s outlet is very hot and 

    can cause the hose to melt if the device is not  

    used  properly.  In  order  to  avoid  heat  from  

    building up directly behind the opening where  

    the fog emerges please ensure that there are  

    no kinks in the first meter of hose and that the  

    hose runs in a straight line from the unit! 

5.2. Operating the unit

•  Be sure to follow the advice for emergency power ge- 
  nerators (see item 2.3.)!
•  The mains plug (10) must be connected to a Schuko  
  socket (230 V/50 Hz).
•  A dot will appear in the bottom right-hand corner of the  
  plastic foil keypad (0).
•  Press “ON” to power on the unit. The blower fan will  
  run in idle. 
•  The green LEDs light up to indicate that fog generator  
  is ready to use after approx. 7 min (warm-up phase). 
•  Press the + and – keys to select air and fog volume  
  settings from 1 – 10.

5.3. Powering off

•  Switch the device to fog volume setting “0” at the end  
  of the procedure and allow to cool off for 5 minutes.  
  The induced ventilation (at air volume setting “0”) is  
  perfectly sufficient.
•  Press “OFF” to switch off the device.
•  Remove the plug from the mains socket.

Do NOT switch the unit off and do NOT disconnect

    the unit from the mains power supply imme- 

    diately after use!
    The generator needs to cool down for at least  

    5 minutes after each use! The remains of the  

    fog fluid are removed from the burning chamber  

    during  this  pressure  cooling  phase  in  order  

    to  prevent  any  condensation  damage  from  

    occurring.

06. Cleaning and Maintenance

6.1. Cleaning and maintenance

•  The  blue  filter  mats  (9)  must  be  cleaned  and  re- 
  placed when necessary. This depends on the level  
  of contamination and the amount of wear and tear  
  that they have been subjected to.
•  Please make sure that the fog device does not run  
  without fluid. This can seriously damage the pump.

Use  original  FS-100  fog  fluid  from  TROTEC 

    only. Other fluids, including non-approved fluids  

    like those used in discotheques for example,  

    can  contain  a  higher  proportion  of  water  

    which  can  cause  sooting  in  the  burning  

    chamber, which in turn can severely damage  

    your product!

•  Turn the condensate drain plug (3) to drain off any  
  condensate that many have formed around the fog  
  exit opening (1). 
•  Use solvent-free cleaning agents only. 

6.2. Storage

•  The FS 100 can be stored in the optionally available  
  carry case.
•  Be sure to select a safe and dry storage place, espe- 
  cially when storing over longer periods.
•  Keep out of the reach of children! Make sure that the  
  fog device is stored in a safe place!

Содержание TROTEC FS 100

Страница 1: ...2 962 400 Fax 49 2452 962 200 www trotec de E Mail info trotec de DE Bedienungsanleitung Nebel Rauchgassimulator A 1 EN Operating Instructions Fog and Smoke Gas Simulator B 1 FR Notice d utilisation Machine à fumée et brouillard C 1 FS 100 TRT TR BA FS100 HS 001 INT ...

Страница 2: ... Telescopic guide rod up to 6 m with quick locking device 02 Safety Notes 2 1 General information Fog can activate smoke detectors Do not drink or swallow the fog fluid Keep out of reach of children Do not open any unit that is connected to a mains supply and do not leave unsupervised 2 2 Instructions when using the FS 100 The device may NOT be placed in a location that is either flammable combust...

Страница 3: ...d is therefore easily inflammable 4 2 Changing the canister Pull back the catch sleeve 5 to release the nozzle 4 Remove the empty canister 8 from the bracket Remove the canister lid 6 from the empty canister and place on the full canister Place the full canister in the bracket Push the nozzle firmly back into the hose connection 05 Operating the Unit 5 1 Selecting a location The location in which ...

Страница 4: ...he unit off and do NOT disconnect the unit from the mains power supply imme diately after use The generator needs to cool down for at least 5 minutes after each use The remains of the fog fluid are removed from the burning chamber during this pressure cooling phase in order to prevent any condensation damage from occurring 06 Cleaning and Maintenance 6 1 Cleaning and maintenance The blue filter ma...

Страница 5: ...ox 7 min 09 Certificate of Non Objection Certificate of non objection for the fog fluid Fog Fluid FS 100 This is to certify that our fog fluid FL FS 100 does not present a hazardous working material in accordance with 3 3a Chemical Law of 16 09 1980 with mo difications made on 14 03 1990 Text Edition of BGBl German Civil Code 1 1990 page 522 The modifi cation of Annex 1 of 05 06 1991 BGBl 1 page 1...

Отзывы: