GENERAL SPECIFICATIONS

AC Receptacle:

2 – Dual Three-prong

Battery Polarity Protect:

Yes (Fuse)

DC Fuse (Recommended):

70 A

Dimension (L x W x H):

13 x 6.25 x 3.75

Efficiency:

88%

Output Short Protect:

Yes (Button Breaker)

Output Waveform:

Pure Sine Wave (<3% Thd)

Operating Temperature Range:

32

°

 F – 158

°

 F (0

°

 Fc – 40

°

 C)

Overload Protect:

Yes

Storage Temperature Range:

-22

°

 F - 158

°

 F (-30

°

 C – 70

°

 C)

Part Number:

79400 With Outlets

Part Number:

79405 Hardwired

Thermal Protect:

50 +/-5 Deg C

Weight:

13 Lbs

ELECTRICAL SPECIFICATIONS

Battery Low Shutdown:

10.5 VDC

Continue Output Power:

400 W

Input Voltage Range:

10.5 – 15.3 VDC

Input Full Load Current:

40 A

No Load Power Draw

0.5 A

Output Frequency:

60 +/- 0.05 Hz

Output Power:

400 Watts

Output Voltage (At No Load):

120 Vac Rms +/- 3 V

Output Voltage (At Full Load):

120 Vac Rms +/- 5 V

Peak Output Power:

1000 Va Surge For 5 Seconds

CAUTION:

 ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:

(A)

WELL VENTILATED

(B)

NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE

(C)

OUT OF REACH FROM CHILDREN

(D)

AWAY FROM WATER / MOISTURE, OIL OR GREASE

(E)

AWAY FROM ANY FLAMMABLE SUBSTANCE

4

TRUEPOWER 400PS FEATURES

1. ON / Off Switch

 turns the inverter to ON or to OFF.

2. Shore Power light 

illuminates when you are connected to shorepower. (shorepower

     refers to the AC input power from a utility grid, generator or external  AC source)

3. Inverter / Fault Light

 illuminates Green when the inverter is operating and

    illuminates Red for fault conditions such as over temperature, output overload,
    or battery over voltage.

4. Two AC Outputs

 to power connected appliances.

5. Supplemental Circuit Protection Button

 may trip if there is an over-current (over

    10 amps) or a short circuit.

6. GFCI

 opening enables the Reset and Test monthly capabilities.

7. Fan 

(internal) activates when the internal temperature of the inverter increases.

    The fan speed varies with the internal temperature and turns off when the inverter
    cools down.

1. DC Input Cables
2. AC Receptacles
3. AC Input cord for shorepower
4. Wiring box access panel

 (Top panel)

5. AC Strain Relief

 for hardwiring

6. Chassis ground lug
7. Remote control jack
8. Mounting flanges

 (Side panel)

9. Ventilation openings

 provides

    air circulation (Side panel)

T r u e P o w e r 4 0 0 P S   F e a t u r e s

S p e c i f i c a t i o n s

15

Figure 2

9

8

4

6

7

1

2

3

5

Remote

DC Grounding

Connector

AC Output

AC Input

DC Input

Figure 1

6

7

5

4

3

2

1

RESET

RESET

TEST

TEST

Shore ON

Red: Inverter Fault

Green: Inverter ON

POWER STATUS

POWER

AC SHORE
BREAKER

Содержание 79400

Страница 1: ...om or call ProMariner directly at 1 800 824 0524 30 am to 5pm Eastern Time MPORTANT SAFETY NOTICE SAVE THESE INSTRUCTIONS ease read all safety operating and installation instructions before installing applying AC power to your ProMariner On Board Solutions power inverter odels Part No Description uePower400PS 79400 GFCI Protected Outlets uePower400PS 79405 Hardwired OnBoard Solutions A ProMariner ...

Страница 2: ...ns on your recent purchase of the TruePower400PS Power Inverter or over 30 years ProMariner has been a leading designer and manufacturer of ower conversion products On Board Solutions serves customers in the automotive ecreational vehicle industrial and mobility markets and is a proud division of roMariner We have expanded our offering to include our latest line of ruePower400PS Power Inverters ea...

Страница 3: ......

Страница 4: ...to 400 watts of ontinuous power and with a surge rating of 1000 watts it can power complete ntertainmentsystemsincludingtwo27 televisions oritcouldalsopowersmallappliances hargers and power tools he TruePower400PS sine wave inverter includes a built in transfer switch that utomatically transfers between inverter and incoming AC power The inverter comes andard with dual AC outlets and AC hardwire c...

Страница 5: ...shall be on the condition and agreement that Professional Mariner HALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND Some states do not low the exclusion or limitation of incidental or consequential damages so the above limitations may not apply you ProfessionalMarinerneitherassumesnorauthorizesanypersonforanyobligationorliabilityinconnection ith the sale of this product o make...

Страница 6: ...a short circuit GFCI opening enables the Reset and Test monthly capabilities Fan internal activates when the internal temperature of the inverter increases The fan speed varies with the internal temperature and turns off when the inverter cools down DC Input Cables AC Receptacles AC Input cord for shorepower Wiring box access panel Top panel AC Strain Relief for hardwiring 6 Chassis ground lug 7 R...

Страница 7: ...e than 12 6 volts DC The inverter will automatically restart Turn the inverter to Off Disconnect the DC wiring Use proper wiring and ensure all connections are secure Problem Cause Solution AC input cord is connected to shorepower but appliance s arenotpoweredfromshorepower ACInputlightisilluminated GFCI has tripped Reset the external breaker Disconnect all appliances Check the AC wiring and press...

Страница 8: ...lercablemaycausetheinvertertoshutdownunderaheavyload Ins talla tion G uide line s 6 Minimum Recommended DC Input cable copper AWG Minimum Recommended Cable Size AWG No 6 No 4 No 2 No 0 Cable Length Battery to Inverter Each Cable 0 10 Feet 10 15 Feet 15 30 Feet 30 40 Feet C Fuse and Disconnect or DC Circuit Breaker The DC fuse and disconnect switch or heDCcircuitbreakershallberated60amps Additional...

Страница 9: ...r or ProMariner to have a qualified chnician inspect the unit esetting as the Result of an Overload he TruePower400PS has a high surge capacity of 1000 watts for 5 seconds the appliance s connected to the unit try to draw excess power for more than seconds the TruePower400PSwill shut down and the Red Fault light will illuminate fter removing the overload condition the TruePower400PS will cycle thr...

Страница 10: ...ions Turn the inverter On Off switch to Off Locate the wiring box access panel and remove the two screws to access the iring box as illustrated in Figure 5 gure 5 Removing the Two Screws on the Wiring Box Access Panel Remove the wiring box access panel from the unit Loosen the clamping nut of the Strain Relief Locate the terminal block he three terminals are labeled as follows L Line N Neutral G G...

Страница 11: ... either the ON or Off position verter Mode If the ON Off switch is in the ON position the TruePower400PS will utomatically supply the appliance s with the inverter power if the shorepower source ils or becomes disconnected NSTALLING YOUR REMOTE CONTROL Find a location for the remote with enough area to mount the 1 3 4 by 2 1 4 panel Using tape painters masking tape is preferred cover the area wher...