Appendix A. Possible Errors
This Section lists all possible error messages that may be generated during the
TR510E’s normal operation. The table below does not apply to the Test and
FMM modes of the TR510E (see Sections 5 and 6 respectively for complete
details on errors generated in these modes).
LED
Error
Description/ Remedy
Read
error
ID-card read error. Read the card again
Database
full
The database is full and new record cannot be
added.
Error 4
Incorrect setting value. Reinitialize the TR510E by
issuing the R-command
Error 5
The database is corrupted. First, try to power the
TR510E off and back on again. If this doesn’t
help, initialize the database using the E-command
or recover the database using the M-command
Error 6
Time/date is not set. Use the S-command to
correct the problem or reinitialize the TR510E
using the R-command
Appendix B. Interface connector pin assignment
#1
TX+
#2
TX -
#3
RX+
#4
No connection
#5
No connection
#6
RX-
#7
No connection
#8
No connection