TR510E User’s Manual
39
The TR510E features a relay that can be used for external bell control. Up
to 7x32 different bell times can be specified for one week to activate the bell.
These 7x32 bell times are programmed into 7 tables from Sunday to Saturday,
group-2 registers 00H-1FH program for Sunday table, group-2 registers 20H-
3FH program for Monday table, group-2 registers 40H-5FH program for
Tuesday table, group-2 registers 60H-7FH program for Wednesday table,
group-2 registers 80H-9FH program for Thursday table, group-2 registers A0H-
BFH program for Friday table, and group-2 registers C0H-DFH program for
Saturday table. Each table has 32 bell table entries, each
bell table entry
consists of 2 fields: ‘time’ field (set through these group-2 registers 00H-DFH)
and a corresponding ‘enable/disable’ field (set through group-3 registers 00H-
DFH).
Bell table (Week mode), enable/disable (group-3 registers 00H-DFH)
Set
Possible error codes:04, 07
Command
J
RR,SS
Reply
A
Get
Possible error codes: 04, 07
Command
KRR
Reply
A
SScc
RR
- register number (group 3) in the Hex form (00H-DFH),
SS
- state (00:
disabled, 01: enabled),
cc
- checksum
The TR510E features a relay that can be used for external bell control. Up
to 7x32 different bell times can be specified for one week to activate the bell.
These 7x32 bell times are programmed into 7 tables from Sunday to Saturday,
group-3 registers 00H-1FH program for Sunday table, group-3 registers 20H-
3FH program for Monday table, group-3 registers 40H-5FH program for
Tuesday table, group-3 registers 60H-7FH program for Wednesday table,
group-3 registers 80H-9FH program for Thursday table, group-3 registers A0H-
BFH program for Friday table, group-3 registers C0H-DFH program for Saturday
table. Each table has 32 bell table entries, each
bell table entry
consists of 2
fields: ‘time’ field (set through group-2 registers 00H-DFH) and a corresponding
Содержание TR510E
Страница 1: ...TR510E EXPRESS Time Recorder V1 5 4...
Страница 40: ...TR510E User s Manual 40 enable disable field set through these group 3 registers 00H DFH...
Страница 53: ...TR510E User s Manual 53 7 Click X close button...
Страница 57: ...TR510E User s Manual 57 c Select Set M to assign the new ID...
Страница 61: ...TR510E User s Manual 61 h Select Set M to assign the new ID...