Z1200WASH
10
- 3 - FUNCTION AND SETTINGS
3.1 OPERATION
Connect the supplied main cable to a socket (200-240V~/50-60Hz). Unlock the PAN (3) and TILT (4) mecha-
nism. Switch on the unit with the power switch (16). Shortly after that the Z1200WASH is ready for opera-
tion. After operation, switch off the unit with the power switch.
3.2 BASIC
Access control panel functions using the two panel buttons and a Jog wheel (fig.6).
[MENU]
[ENTER]
[JOG WHEEL]
Used to access the menu or to return to a previous menu option.
Used to select and store the current menu or confirm the current function value or option
within a menu.
To choose a menu item and set a function.
Fig.6
MENU
ENTER
P O W E R
D M X
Every time you turn on the unit, it will run built-in program to reset all motors to their home position, the
display will show as (fig.7). It will show warning sign if it goes wrong during resetting and you can press the
MENU button to view the error information. After that the unit will be ready to receive DMX signal and the
display will show as (fig.8).
Explanation of fig.8
Base. 40°C
Present temperature of base CPU is 40°C
001
Present start address
Md.1 24Ch.
Present channel mode is mode 1 (24 channels mode)
Lamp. 30°C
Present temperature of lamp is 30°C
Warning signal blinking direct resetting error
Fig.7
Z1200WASH
Fig. 8
DMX Address
Md.1
Lamp. 30°C
001
24Ch.
Base. 40°C
!
!