background image

PROLIGHTS - Sunrise 

2IP

12

9 - MENU STRUCTURE 

The following chart describes the MENU tree of the product, the terms shown in 

BOLD

 indicates the 

default settings.

MENU 

1

CONNECT

DMX ADDRESS

001

-512

DMX MODE

UNO

TUNGSTEN EMULATION ON
TUNGSTEN EMULATION OFF

BASIC

TUNGSTEN EMULATION ON
TUNGSTEN EMULATION OFF

STANDARD

EXTENDED

2

SETUP

SCREEN

BACKLIGHT

ON

10 s

20 s

30 s

Allows  you  to  select  the 

timing after that display 

will switch automatically off 

when unactive.

FLIP DISPLAY

ON

OFF

Allows  you  to  rotate  the 

display by 180°.

KEY LOCK

ON

OFF

Allows you lock the buttons 

on the control panel by a 

password.

Press following 

combinations (password) 

in order to access to the 

user menu : UP, DOWN, UP, 

DOWN, ENTER,

TEMPERATURE UNIT

°C

°F

To  choose  the  desired  unit 

of  temperature  measure

-

ment.

TRANSFER 

CONFIGURATION

NO DMX ADDRESS

WITH DMX ADDRESS

To  transfer  the  same  menu 

settings of one fixtures to all 

the other in the daisy chain, 

including  or  not  the  dmx 

address.

3

ADVANCED

DIMMER CURVE

LINEAR

S-CURVE

SQUARE LAW

INVERSE SQUARE LAW

To  choose  the  dimmer 

curve.

DIMMER SPEED

AUTO

FAST

MEDIUM

SLOW

To  choose  the  dimmer 

speed.

WHITE

CALIBRATION

OFF

Disable the White Calibra-

tion.

MANUAL

TUNGSTEN 1 <125 ÷ 255>

TUNGSTEN 2 <125 ÷ 255>

AMBER <125 ÷ 255>

To  adjust  the  max  level  for 

each color.

TUNGSTEN EMU-

LATION

ON

OFF

Emulation of halogen lamp.

LED

FREQUENCY

600Hz

1200Hz

2000Hz

4000Hz

6000Hz

25KHz

Select PWM  frequency

DMX FAULT

HOLD

BLACKOUT

STAND ALONE

To choose the behaviour of 

fixture in case of dmx signal 

lost.

INVERT

MAPPING

ON

OFF

To invert the pixel layout of 

the fixture.

FACTORY RELOAD

NO

YES

To  reset  the  unit  to  factory 

default settings.

Содержание Sunrise 2IP

Страница 1: ...USER MANUAL REV 03 11 20 English version Sunrise 2IP IP rated modular LED blinder with 2x75W LED WW and Tungsten emulation...

Страница 2: ...economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolight...

Страница 3: ...TION 09 CONNECTION DAISY CHAIN 09 CONNECTION OF THE DMX LINE 09 CONSTRUCTION OF THE DMX TERMINATION 10 DMX ADDRESSING 10 8 CONTROL PANEL 11 DISPLAY AND BUTTONS LAYOUT 11 9 MENU STRUCTURE 12 10 RDM FUN...

Страница 4: ...are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components are...

Страница 5: ...verheating and will damage the fixture Damages caused by inadequate cleaning or maintenance are not covered by the product warranty T 75 C c Temperature of the external surface The surface of the fixt...

Страница 6: ...ntains a lithium ion battery Don t throw the unit into the garbage at the end of its lifetime Make sure to dispose according to your local ordinances and or regulations to avoid polluting the environm...

Страница 7: ...ents for 4 pcs of SUNRISE2IP SR2IPHB01V hanging bracket for SUNRISE2IP 1x2 configuration fixture vertical SR2IPHB02V hanging bracket for SUNRISE2IP 2x2 configuration fixture vertical SR2IPHB04H hangin...

Страница 8: ...re it against failure of primary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use re...

Страница 9: ...r from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switch...

Страница 10: ...s to the control panel functions 4 HOLES for fast lock omega brackets 5 SAFETY EYE to attach safety cable 6 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 7 DMX OUT 5 p XLR 1 GND 2 sign 3 sign 4 N C 5...

Страница 11: ...connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male connec...

Страница 12: ...e executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set the...

Страница 13: ...nd buttons for access to the control panel functions MENU Used to access the menu tree or to return a previous menu window UP Browse upwards through the menu list and increases the numeric value displ...

Страница 14: ...NIT C F To choose the desired unit of temperature measure ment TRANSFER CONFIGURATION NO DMX ADDRESS WITH DMX ADDRESS To transfer the same menu settings of one fixtures to all the other in the daisy c...

Страница 15: ...CE LABEL SOFTWARE VER SION RDM UID 15D00228 5 STAND ALONE MASTER SLAVE MASTER SLAVE Allow you to link and oper ating in synk multiple units without a DMX console Choose a unit to perform as the Master...

Страница 16: ...x Modulation Frequency Description 0x0348 x x Output Response Time 0x0345 x x Output Response Time Description 0x0346 x Parameter Description 0x0051 x x Product Detail ID List 0x0070 x Sensor Definiti...

Страница 17: ...ecific PID 0 BLACKOUT 1 HOLD 2 STANDALONE 0x82DD x CLEAN ALL DATA 0 NO 1 YES 0x82C8 x CURRENT HOURS 0x82C5 x EFFECT 0x8209 x EFFECT_SPEED 0x8210 x INVERT MAPPING 0 OFF 1 ON 0x82E1 x MAINTENANCE TIME A...

Страница 18: ...r speed slow 000 051 052 101 102 152 153 203 204 255 000 4 5 TUNGSTEN EMULATION OFF ON 000 127 128 255 000 5 DIMMER 1 000 255 255 6 DIMMER 2 000 255 255 6 DIMMER 1 000 255 255 7 DIMMER 1 FINE 000 255...

Страница 19: ...Led frequency 6000hz Led frequency 25khz Dmx fault hold Dmx fault blackout Dmx fault stand alone Invert mapping on Invert mapping off Stand alone master Stand alone slave Stand alone effect 1 Stand a...

Страница 20: ...NGING BRACKET CODE SR2IPHB02H INCLUDED 388 15 3 65 2 6 104 4 1 90 3 5 90 3 5 104 4 1 13 0 5 173 6 8 50 2 0 Mount the hanging bracket and tighten the screws and the two knobs on the sides for the hangi...

Страница 21: ...ET CODE SR2IPHB01V OPTIONAL 205 8 1 257 10 1 50 1 9 65 2 6 32 1 3 70 2 8 70 2 8 33 1 3 13 0 5 Mount the hanging bracket and tighten the screws and the two knobs on the sides for the hanging a single u...

Страница 22: ...8 15 3 257 10 1 65 2 6 104 4 1 90 3 5 90 3 5 104 4 1 50 2 0 13 0 5 1 Using the rear brackets SR2IPOS to connect the units 2 Mount the hanging bracket and tighten the screws and the two knobs on the si...

Страница 23: ...173 6 8 50 2 0 105 4 1 90 3 5 90 3 5 90 3 5 90 3 5 90 3 5 90 3 5 105 4 1 13 0 5 1 Using the rear bracket SR2IPOS to connect the units 2 Mount the hanging bracket and tighten the screws and the two kno...

Страница 24: ...ersonnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component lif...

Страница 25: ...ors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after...

Страница 26: ...Note...

Страница 27: ......

Страница 28: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Отзывы: