7
HERO H150F
Refer to the table below to access and settings:
BUTTON
INSTRUCTIONS
FUNCTION
Press the button FUNCTION until the display indicates:
[INTERVAL SET]
,
[DURATION SET], [TIMER
OUT], [VOLUME OUT], [DMX 512 ADD], [WIRELESS ON]
or
[FLUID SENSOR].
•
[INTERVAL SET] -
Use the buttons UP/DOWN to adjust the intervals between the individual fog
outputs in timer mode within the range of 1 and 200 seconds.
•
[DURATION SET] -
Use the buttons UP/DOWN to adjust the duration of the fog outputs in timer
mode within the range of 1 and 200 seconds.
•
[TIMER OUT] -
Use the buttons UP/DOWN to adjust the fog output volume in timer mode within
the range of 1 % and 100 %.
•
[VOLUME OUT] -
Use the buttons UP/DOWN to adjust the fog output volume in continuous
mode within the range of 1 % and 100 %. To set the unit to continuous fog output in continuous
mode, select »NON STOP BURST« below a value of 1 % or above a value of 100 %.
NOTE: When setting a fog output volume higher than 30 % for continuous operation, the fog
machine occasionally needs to stop the fog output to reheat. When »NON STOP BURST« is selected,
the fog machine adjusts the fog output volume and heater temperature automatically and does not
need to stop the fog output to reheat.
•
[DMX 512 ADD] -
Use the buttons UP/DOWN, to set the machine to the same address as on your
DMX controller. Please refer to chapter DMX512 settings for moreinformation on DMX operation.
•
[WIRELESS ON]
- Use the buttons UP and DOWN to deactivate the wireless function (indication
»Wireless Off«) and to reactivate it (indication »Wireless On«).
•
[FLUID SENSOR] -
Use the buttons UP and DOWN to deactivate the fluid sensor (indication
»Fluid Sensor Off«) and to reactivate it (indication »Fluid Sensor On«).
UP
Button for increasing numerical value
DOWN
Button for decreasing numerical value
TIMER
Pushing this button, the machine will work according to the set up interval time, duration and
adjusted volume.
VOLUME
Pushing this button, the unit will issue the volume in accord with VOLUME OUT.
MANUAL
Pushing this button, the unit will issue its maximum volume. When the button is released the unit
will return to its original state. This function can be executed under any circumstances.
Continuous operation
Press the button
[VOLUME]
, to activate continuous fog output. The display indicates »Volume« followed by
the value that was set in menu item »Volume Out« or »NON STOP BURST« when continuous fog output was
selected. To stop the fog output, press the button
[VOLUME]
once again.
NOTE - When a fog output volume higher then 30 % was set for continuous operation, the fog machine oc-
casionally needs to stop the fog output to reheat. When »NON STOP BURST« was selected, the fog machine
adjusts the fog output volume and heater temperature automatically and does not need to stop to reheat.