Montageanleitung /
Installation manual
MBN GmbH
Balthasar-Schaller-Str. 3
86316 Friedberg
Germany
www.proled.com
44
Touch the
SET WAIT/SPEED BUTTON
to open the set wait/speed window.
On the left side the WAIT time can be adjusted with the '
+'
and '
-'
buttons.
On the right side the SPEED time can be adjusted with the '
+'
and '
-'
buttons.
In the center of the screen the changing range can be selected. The maximum
selectable time can be 2 hours.
GRADE radio group
– parameter adjust by selected value (0.05sec, 0.1sec,
1sec, 10sec, 1min)
WAIT +
wait time is increased by selected grade value
WAIT -
wait time is decreased by selected grade value
SPEED +
speed time is increased by selected grade value
SPEED -
speed time is increased by selected grade value
Immediate load:
After program start the scene will be loaded immediately
without the selected speed time.
CANCEL
– the window closes without any changes in memory
OK
– the window close and the software will save all modifications
DELETE PROGRAM
Touch and hold touched one program button to open the
EDIT BUTTON
window.
Touch the
DELETE BUTTON
to delete the selected program.
ZONA SYNC
If you want start and stop programs same time in different zone, then here you can
set it.