4. TECHNICAL CHARACTERISTICS
Power supply
Units for alternating current
Units for direct current
Tension
230 VAC +5% -10% CAT II
12 VDC +10% -5%
Frequency
50 - 60 Hz
--------
Energy consumption
Inferior to 58 VA (at rest 2,7 VA)
Inferior to 7 W (at rest 0,6 W)
Input
0.630 A, T type, 250V (slow)
0.8 A, T type, 250V (slow)
Fuses
Outlet
2 A, F type, 250V (fast)
3.15 A, F type, 250V (fast)
Keeping the memory which can be
erased when there is a power cut
Battery, more than 72 hours
Condenser, 24 hours
Outlets
Number 6,12,18+1 (according to model)
Inputs
Number 5
Type
By relay contact, with potential of 24
VAC (Internal transformer) or 12VDC
Type
Optolinked, to connect to
contacts free of potential
Limits
40 VAC / 30 VDC, 1 Amp
Atmosphere
Temperature
0º C to 45º C
Weight
Unit in mounting box
2,2 Kg
Humidity
< 85 %
(approximate)
Unit to build-in
2,7 Kg
Height
2000
m
Pollution
Grade
II
Memory backup
Clock, consults
Battery or condenser
Programme, parameters
Non erasable
DECLARATION OF CONFORMITY
It follows the 89/336/CEE Guidelines for the Electromagnetic Compatibility and the
73/23/CEE Guidelines of Low Tension for the Fulfilment of the Product Security. The
fulfilment of the following specifications was demonstrated as indicated in the Official Diary
of the European Communities:
Emissions EN 50081-1:94 EN 55022:1995 Class B Radiated and conducted emissions.
Immunity EN 50082-1:94
EN 61000-4-2 (95)
Immunity to electrostatic discharges.
EN 61000-4-3 (96)
Immunity to the electromagnetic field of radioelectric
frequency.
EN 61000-4-4 (95)
Immunity to fast transitional in common way.
EN 61000-4-5
Immunity to overloads in the power supply.
EN 61000-4-11
Immunity to lacks and power cuts.
Harmonics
EN 61000-3-2 (95)
Current harmonics.
Fluctuations
EN 61000-3-3 (95)
Tension fluctuations.
Low tension guidelines
EN 61010-1
Security requirements of measurement electric units,
control and use in laboratory.
Symbols which may appear
in the product
Protection earth
terminal
Danger, risk of
electroshock
Double
insulation
This symbol indicates that the electrical and electronic equipment should not be disposed of as
general household waste at its end-of-life. Instead, the product should be handed over to the
applicable collection point for the recycling of electrical and electronic equipment for proper
treatment, recovery and recycling in accordance with your national legislation.