P r o g r a m m a E l e c t r i c A B
Z P - B M 0 1 D R 0 7 A
6 3
E G I L
10.3 Error messages
Message:
Incorrect Status, Check hook-
up, Set analog off
Possible cause:
The motion transducer is not
moving or moving less than 5%,
but the time input detects a
change of state.
Remedy:
Check the connection &
mounting of the Motion
transducer.
Message:
Not calibrated, Adjust current,
Adjust voltage
Possible cause:
The unit has a new EPROM
,
and the calibrations data are not
found.
Remedy:
Calibrate the current & voltage
input.
Message:
EPROM conflict
Possible cause:
Mixing of EPROM versions
between the Master & the 1st or
2nd slave EPROMs.
Remedy:
Contact your GE representative
for Programma Products.
Message:
ROM ERROR
Possible cause:
Internal fault in Egil, checksums
of ROM do not match.
Remedy:
Turn off the power. Contact your
Programma Electric AB
representative.
Message:
Not calibrated (showed at start-
up)
Possible cause:
Calibration data are missing.
Remedy:
Calibrate the unit by choosing
CALIBRATION from the MAIN
menu. For more information, see
Chapter 11 (Calibration).
Message:
Memory corrupted
Possible cause:
The settings which you try to
recall are corrupt.
Remedy:
Press ESC. If you just turned on
the power, the default settings
will be loaded, otherwise try to
recall the default or another
setting.
If you cannot correct this, contact
your Programma Electric AB
representative.
Message:
Memory is empty
Possible cause:
The memory is empty because
you have not recorded any data
or you have interrupted the last
recording process.
Remedy:
Press ESC. Run a measurement.
Message:
Printer Error
Possible cause:
The printer is out of paper or the
head lever is up.
Remedy:
Press ESC. Load new paper or
close the head lever.
Message:
Setting changed
Possible cause:
For CENTRE POINT - Egil is not
able to take your value as the
centre point of the plot. Egil has
made its own proposal.
For TIME AFTER UPPER & TIME
BEFORE UPPER - due to round-off
errors, the location of the lower
point is slightly shifted.
Remedy:
Press ESC to see the value
proposed by Egil. You can keep
the value or change it.
Press ESC to see the
recalculated value. You can keep
it or set another one.
Message:
Pulse errors
Possible cause:
In OCO sequence open delay
pulse + close pulse delay are
shorter than open pulse length
No. 1 (i.e. opening pulses are
overlapping).
Remedy:
Press ESC, change the
parameters and start a new
measurement.
Motion option
Option - >
Message:
Overflow
Possible cause:
Motion calculation failed because
the value is greater than 1000
mm (39.4”).
Remedy:
Press ESC and check the
calibration.
Message:
Not calibrated, press ESC
(showed at measurement)
Possible cause:
Motion calculations failed
because of wrong conditions.
Содержание EGIL BM-19070
Страница 1: ...EGIL Breaker Analyzer User s Manual...
Страница 2: ......
Страница 7: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 7 E G I L...
Страница 9: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 9 E G I L...
Страница 15: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 1 5 E G I L...
Страница 19: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 1 9 E G I L...
Страница 20: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 E R 0 7 A 2 0 E G I L 5 Control panel...
Страница 47: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 4 7 E G I L...
Страница 49: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 4 9 E G I L...
Страница 61: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 6 1 E G I L...
Страница 65: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 6 5 E G I L...
Страница 75: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 7 5 E G I L...
Страница 78: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 E R 0 7 A 7 8 E G I L...
Страница 79: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 7 9 E G I L...
Страница 80: ...Subject to change without notice Printed matter No ZP BM01E R07A Doc BM0087JE...