ELECTRONIC CONTROL PANEL 

 

 

Page 9 

 

PROGRAMMING INSTRUCTIONS - 

BASIC SETTINGS 

 

 

Before entering the programming mode, make sure that 

the appliance is in the service mode.  

 

 

In  case  no  button  is  pressed  in  a  period  of  5  min,  the 

control panel will automatically return to the service mode; 
any changes made will NOT be saved! 
 
1.

 

Press the scroll   button; the display will show: 

 
 
 

 

Press  the  up 

  or  down 

  button  to  set  the 

language

 
2.

 

Press the scroll   button again; the display will show: 

 
 
 

 

Press the up 

 or down 

 button to set the time of 

day

 

3.

 

Press the scroll   button again; the display will show:  

 
 
 

 

Press the up   or down   button to set the number 
of days between regenerations

 
4.

 

Press the scroll   button again; the display will show:  

 
 
 

 

Press the up   or down   button to save the settings 
into the NOVRAM® and exit the programming mode. 

 

 

The  regeneration  cycle  is  necessary  to  wash  out 

impurities  that are  captured  in the filter  media during the 
service  cycle,  and  to  prevent  ‘caking’  of  the  filter  media, 
which  may  result in  an  increase of  pressure drop  over the 
water filter. Typically a regeneration every 4 days should be 
sufficient. In case of high flow rates, excessive water usage 
or a high concentration of impurities in the incoming water, 
it may be necessary to lower the number of days between 
regenerations.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PROGRAMMING INSTRUCTIONS - 

CONFIGURATION PARAMETERS 

 

 

Before entering the programming mode, make sure that 

the appliance is in the service mode.  

 

 

All  configuration  parameters  on  this  appliance  have 

been  pre-programmed  in  the  factory,  to  offer  optimal 
performance in a wide range of applications and situations. 
Nevertheless it may be necessary or desirable to change any 
of  these  parameters,  to  further  optimize  the  appliances 
performance  or to adapt it  to  the  specific  requirements of 
the installation.  

 

 

In  case  no  button  is  pressed  in  a  period  of  5  min,  the 

control panel will automatically return to the service mode; 
any changes made will NOT be save! 
 
1.

 

Press the scroll 

 button and hold it for 5 sec until the 

display shows: 

 
 
 
2.

 

Within  10  sec,  press  the  up 

  button;  the  display  will 

show: 

 
 
 

 

Press the up 

 or down   button to set the units of 

measure (Metric or US)

 
3.

 

Press the scroll   button again; the display will show: 

 
 
 

 

Press  the  up 

  or  down 

  button  to  activate  the 

maintenance  reminder  function  by  setting  the 
maintenance interval, or deactivate the maintenance 
reminder function

 
4.

 

Press the scroll   button again; the display will show: 

 
 
 

 

Press the up 

 or down 

 button to set the length 

of the regeneration cycle

 

Press the scroll   button again to advance to the next 
regeneration cycle. 

Cycle 1 

Backwash 

Cycle 2 

No function 

Cycle 3 

Fast rinse 

Cycle 4  

No function (PF-GAC1,5 & PF-AG1,5) 

 
5.

 

Press the scroll   button again; the display will show:  

 
 
 

 

Press the up 

 or down 

 button to set the time of 

regeneration

 
6.

 

Press the scroll   button again; the display will show:  

 
 
 

 

Press the up   or down   button to save the settings 
into the NOVRAM® and exit the programming level. 

Language:English

 

Set time:  8:01

 

Interval:Days 

Cycle 1:  XX min

 

System Check

 

Regen @     0:00 

Exit 

Exit 

MaintInt: 24mths

 

Units:Metric

 

Содержание PF-AG1

Страница 1: ...2017 erie water treatment TM EN PF GAC_AG Rev2017 01 Technical Manual WATER FILTER Models PF GAC1 PF AG1 PF GAC1 5 PF AG1 5...

Страница 2: ...Page 12 Default configuration parameter settings Page 13 Composition overview Page 14 Exploded view PF GAC1 PF AG1 System Page 16 Exploded view PF GAC1 PF AG1 Timer assembly Page 18 Exploded view PF...

Страница 3: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Страница 4: ...ATING TEMPERATURE MIN MAX 4 48 C 39 120 F do not install the appliance in an environment where high ambient temperatures e g unvented boiler house or freezing temperatures can occur the appliance cann...

Страница 5: ...uaranteeing uninterrupted supply of water FILTER MEDIA LOADING 1 Move the pressure tank to the correct installation location position it on a flat and level surface Make sure to leave enough space for...

Страница 6: ...f control valve untreated water outlet of control valve treated water 1 Install the 3 valve connection kit 2 Insert the adaptors in the in out ports on the control valve make sure not to damage the O...

Страница 7: ...tting it into service close the BYPASS valve open the OUT valve slowly open the IN valve 6 After 2 3 minutes open a cold treated water faucet nearby the appliance and let the water run for a few minut...

Страница 8: ...the display shows the time of day and the number of days remaining until the next regeneration REGENERATION MODE In regeneration mode the display shows the remaining regeneration time and the remaini...

Страница 9: ...ode All configuration parameters on this appliance have been pre programmed in the factory to offer optimal performance in a wide range of applications and situations Nevertheless it may be necessary...

Страница 10: ...ere shouldn t be any water leakages BYPASSING THE APPLIANCE Occasionally it may be necessary to put the appliance hydraulically in bypass i e to isolate it from the water distribution system f e in ca...

Страница 11: ...essure tank Clean filter media and control valve increase regeneration frequency Plugged lower and or upper distributor Verify that distributors are free of debris Drain line from control valve flows...

Страница 12: ...AL WIRING DIAGRAMS Page 12 PF GAC1 PF AC1 position switches power lead drive motor service valve NO optional key pad PF GAC1 5 PF AC1 5 optical switch power lead drive motor service valve NO optional...

Страница 13: ...ASH min 10 10 10 Cycle 2 SLOW RINSE min 0 0 0 Cycle 3 PURGE min 3 3 3 Regen 0 00 0 00 0 00 Model PF GAC1 5 PF AG1 5 Filter media cuft 3 4 5 7 10 Interval days 4 4 4 4 4 Cycle 1 BACKWASH min 10 10 10 1...

Страница 14: ...N Control valve incl transformer 1 5 male BSP connections Pressure tank incl distributor assy Underbedding Filter media 1 cuft bag cuft model model type ltr type PF GAC1 5 3 35852 EV1 5TF J 100 1 14x6...

Страница 15: ...Page 15...

Страница 16: ...EXPLODED VIEW PF GAC1 PF AG1 SYSTEM Page 16...

Страница 17: ...Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 38534 Riser tube assembly to be cut to length 5 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 28 298 18 Transformer 230 24V 50 Hz...

Страница 18: ...EXPLODED VIEW PF GAC1 PF AC1 TIMER ASSEMBLY Page 18...

Страница 19: ...157 Worm coupling 9 15 222 Screw drive motor assembly 2x 10 74267 Cable clamp 11 70312 Strain relief power lead 12 75158 Retaining ring worm drive shaft 13 72261 Drive motor 14 75156 Worm drive shaft...

Страница 20: ...EXPLODED VIEW PF GAC1 PF AC1 VALVE BODY Page 20...

Страница 21: ...383 Insert plate 14 568 384 Gasket 15 51 5 105 Spring float valve 16 568 270 4 Float valve 17 568 274 5 Injector green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug sm...

Страница 22: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 SYSTEM Page 22...

Страница 23: ...0 BB Coconut Granular Activated Carbon GAC multiple of 1 cuft A8014 Filter Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 39107 Riser tube assembly to be cut to length 5 EV TD Top dis...

Страница 24: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 TIMER ASSEMBLY Page 24...

Страница 25: ...assembly Service Valve 7 74226 Plug large 2x 8 28 244 1 Plug small 9 28 500 11 Power lead with plug incl with transformer 10 EV 20761 Screw optical sensor 2x 11 74235 Optical sensor 12 15 102 Screw P...

Страница 26: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 VALVE BODY Page 26...

Страница 27: ...or 8 74245 Drain Line Flow Controller 10 0 GPM 3 cuft 74246 Drain Line Flow Controller 15 0 GPM 4 cuft 74247 Drain Line Flow Controller 20 0 GPM 5 cuft 74254 Drain Line Flow Controller 25 0 GPM 7 cuft...

Страница 28: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 PISTON ASSEMBLY Page 28...

Страница 29: ...iption Remark 1 EV 20646 Piston 2 EV 20654 Stem 3 EV 11104 Bushing 4 EV 11105 O ring bushing 2x 5 EV 11080 Seal disk 6 EV 11082 Spacer narrow 2x 7 EV 11081 Spacer wide 3x 8 EV 11078 Compression spacer...

Страница 30: ...ice flow m hr 4 1 2 1 7 2 3 Rinse water usage per regeneration ltr 295 394 492 Backwash flow rate ltr min 23 31 38 Model PF AG1 Filter media cuft 1 2 3 Service flow rate p 1 bar m hr 3 3 4 3 4 3 5 Rec...

Страница 31: ...6 7 Rinse water usage per regeneration ltr 492 738 984 1 230 1 722 Backwash flow rate ltr min 38 57 76 95 133 Model PF AG1 5 Filter media cuft 3 4 5 7 10 Service flow rate p 1 bar m hr 3 7 8 7 8 7 8...

Страница 32: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com...

Отзывы: