INSTALLATION 

 

 

 

Page 6 

INLET & OUTLET 

 

 

We  strongly  recommend  the  use  of  flexible  hoses  to 

connect the appliance to the water distribution system; use 
hoses with a  large diameter in order to limit the  pressure 
loss. 

 

 

We  strongly  recommend  the  installation  of  a  bypass 

system  (not  included  with  this  product!)  to  isolate  the 
appliance  from  the  water  distribution  system  in  case  of 
repairs. It allows to turn off the water to the appliance, while 
maintaining full-flow (untreated) water supply to the user. 
 

only for PF-GAC1 & PF-AG1:  
with factory bypass (optional) 

 

  

Picture 1

 

 = mains water supply (untreated water) 

 = inlet of control valve (untreated water) 

 = outlet of control valve (treated water) 

 = application (treated water) 

1.

 

Screw  the  factory  bypass  onto  the  in/out  ports  on  the 
control  valve  (

&

);  make  sure  to  install  the  gasket 

seals. Tighten the nuts firmly by hand. 

2.

 

Screw  the  connection  kit  with  nuts  onto  the  factory 
bypass  (

&

);  make  sure  to  install  the  gasket  seals. 

Tighten the nuts firmly by hand. 

3.

 

Connect  the  mains  water  supply  to  the  adaptor  on  the 
inlet port of the factory bypass (

). 

4.

 

Connect the application to the adaptor on the outlet port 
of the factory bypass (

). 

 

only for PF-GAC1 & PF-AG1:  
with 3-valve connection kit (not included) 

 

  

Picture 2

 

 = inlet of control valve (untreated water) 

 = outlet of control valve (treated water) 

1.

 

Install the 3-valve connection kit. 

2.

 

Screw the connection kit with nuts onto the in/out ports 
on  the  control  valve  (

&

);  make  sure  to  install  the 

gasket seals. Tighten the nuts firmly by hand. 

3.

 

Connect the IN valve of the 3-valve connection kit to the 
adaptor on the in port of the control valve (

). 

4.

 

Connect the OUT valve of the 3-valve connection kit to the 
adaptor on the out port of the control valve (

). 

5.

 

Connect the mains water supply to the inlet of the 3-valve 
connection kit. 

6.

 

Connect  the  application  to  the  outlet  of  the  3-valve 
connection kit. 

 

only for PF-GAC1,5 & PF-AG1,5:  
with 3-valve connection kit (not incl.) 

 

  

Picture 3

 

 = inlet of control valve (untreated water) 

 = outlet of control valve (treated water) 

1.

 

Install the 3-valve connection kit. 

2.

 

Insert the adaptors in the in/out ports on the control valve 
(

&

); make sure not to damage the O-rings. Install the 

nuts and tighten them firmly by hand. 

3.

 

Connect the IN valve of the 3-valve connection kit to the 
adaptor on the in port of the control valve (

). 

4.

 

Connect the OUT valve of the 3-valve connection kit to the 
adaptor on the out port of the control valve (

). 

5.

 

Connect the mains water supply to the inlet of the 3-valve 
connection kit. 

6.

 

Connect  the  application  to  the  outlet  of  the  3-valve 
connection kit. 

 

DRAIN

 

 

 

We recommend the use of a stand pipe with P-trap.  

 

 

To prevent backflow from the sewerage system into the 

appliance, always install and use an air gap (drain adaptor 
with air gap included with PF-GAC1 & PF-AG1), to connect 
the drain hose to the sewerage system. 

 

 

Lay-out the drain hose in such a way that pressure loss 

is minimized; avoid kinks and unnecessary elevations. 

 

 

Make sure that the sewerage system is suitable for the 

rinse water flow rate of the appliance. 
 

only for PF-GAC1 & PF-AG1 

 

  

Picture 6

 

1.

 

Install  the drain  adaptor to the  sewerage system; it fits 
over a 32 mm pipe or inside a 40 mm pipe adaptor. Ensure 
a permanent and watertight connection. 

2.

 

Connect  a  13  mm  hose  to  the  drain  connection  of  the 
control valve (

); secure it by means of a clamp. 

3.

 

Run the drain hose to the drain adaptor and connect it to 
one of the hose barbs; secure it by means of a clamp. This 
drain line operates under pressure, so it may be installed 
higher than the appliance. 

only for PF-GAC1,5 & PF-AG1,5 

  

Picture 7

 

1.

 

Connect a pipe to the 1” BSP Male drain connection of the 
control valve (

); use an appropriate sealant. 

2.

 

Run  the  pipe  to  the  sewerage  system  and  connect  it, 
ensuring  sufficient air  gap  between  the  end of  the  pipe 
and the sewerage system. This drain line operates under 
pressure, so it may be installed higher than the appliance. 

 

SERVICE VALVE (optional) 

 

  

Picture 8

 

1.

 

Plug the DIN plug on the connection cable of the Service 
Valve  into  the  DIN  socket  at  the  back  of  the  electronic 
timer head of the respective control valve (

). 

 

Содержание PF-AG1

Страница 1: ...2017 erie water treatment TM EN PF GAC_AG Rev2017 01 Technical Manual WATER FILTER Models PF GAC1 PF AG1 PF GAC1 5 PF AG1 5...

Страница 2: ...Page 12 Default configuration parameter settings Page 13 Composition overview Page 14 Exploded view PF GAC1 PF AG1 System Page 16 Exploded view PF GAC1 PF AG1 Timer assembly Page 18 Exploded view PF...

Страница 3: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Страница 4: ...ATING TEMPERATURE MIN MAX 4 48 C 39 120 F do not install the appliance in an environment where high ambient temperatures e g unvented boiler house or freezing temperatures can occur the appliance cann...

Страница 5: ...uaranteeing uninterrupted supply of water FILTER MEDIA LOADING 1 Move the pressure tank to the correct installation location position it on a flat and level surface Make sure to leave enough space for...

Страница 6: ...f control valve untreated water outlet of control valve treated water 1 Install the 3 valve connection kit 2 Insert the adaptors in the in out ports on the control valve make sure not to damage the O...

Страница 7: ...tting it into service close the BYPASS valve open the OUT valve slowly open the IN valve 6 After 2 3 minutes open a cold treated water faucet nearby the appliance and let the water run for a few minut...

Страница 8: ...the display shows the time of day and the number of days remaining until the next regeneration REGENERATION MODE In regeneration mode the display shows the remaining regeneration time and the remaini...

Страница 9: ...ode All configuration parameters on this appliance have been pre programmed in the factory to offer optimal performance in a wide range of applications and situations Nevertheless it may be necessary...

Страница 10: ...ere shouldn t be any water leakages BYPASSING THE APPLIANCE Occasionally it may be necessary to put the appliance hydraulically in bypass i e to isolate it from the water distribution system f e in ca...

Страница 11: ...essure tank Clean filter media and control valve increase regeneration frequency Plugged lower and or upper distributor Verify that distributors are free of debris Drain line from control valve flows...

Страница 12: ...AL WIRING DIAGRAMS Page 12 PF GAC1 PF AC1 position switches power lead drive motor service valve NO optional key pad PF GAC1 5 PF AC1 5 optical switch power lead drive motor service valve NO optional...

Страница 13: ...ASH min 10 10 10 Cycle 2 SLOW RINSE min 0 0 0 Cycle 3 PURGE min 3 3 3 Regen 0 00 0 00 0 00 Model PF GAC1 5 PF AG1 5 Filter media cuft 3 4 5 7 10 Interval days 4 4 4 4 4 Cycle 1 BACKWASH min 10 10 10 1...

Страница 14: ...N Control valve incl transformer 1 5 male BSP connections Pressure tank incl distributor assy Underbedding Filter media 1 cuft bag cuft model model type ltr type PF GAC1 5 3 35852 EV1 5TF J 100 1 14x6...

Страница 15: ...Page 15...

Страница 16: ...EXPLODED VIEW PF GAC1 PF AG1 SYSTEM Page 16...

Страница 17: ...Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 38534 Riser tube assembly to be cut to length 5 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 28 298 18 Transformer 230 24V 50 Hz...

Страница 18: ...EXPLODED VIEW PF GAC1 PF AC1 TIMER ASSEMBLY Page 18...

Страница 19: ...157 Worm coupling 9 15 222 Screw drive motor assembly 2x 10 74267 Cable clamp 11 70312 Strain relief power lead 12 75158 Retaining ring worm drive shaft 13 72261 Drive motor 14 75156 Worm drive shaft...

Страница 20: ...EXPLODED VIEW PF GAC1 PF AC1 VALVE BODY Page 20...

Страница 21: ...383 Insert plate 14 568 384 Gasket 15 51 5 105 Spring float valve 16 568 270 4 Float valve 17 568 274 5 Injector green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug sm...

Страница 22: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 SYSTEM Page 22...

Страница 23: ...0 BB Coconut Granular Activated Carbon GAC multiple of 1 cuft A8014 Filter Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 39107 Riser tube assembly to be cut to length 5 EV TD Top dis...

Страница 24: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 TIMER ASSEMBLY Page 24...

Страница 25: ...assembly Service Valve 7 74226 Plug large 2x 8 28 244 1 Plug small 9 28 500 11 Power lead with plug incl with transformer 10 EV 20761 Screw optical sensor 2x 11 74235 Optical sensor 12 15 102 Screw P...

Страница 26: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 VALVE BODY Page 26...

Страница 27: ...or 8 74245 Drain Line Flow Controller 10 0 GPM 3 cuft 74246 Drain Line Flow Controller 15 0 GPM 4 cuft 74247 Drain Line Flow Controller 20 0 GPM 5 cuft 74254 Drain Line Flow Controller 25 0 GPM 7 cuft...

Страница 28: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 PISTON ASSEMBLY Page 28...

Страница 29: ...iption Remark 1 EV 20646 Piston 2 EV 20654 Stem 3 EV 11104 Bushing 4 EV 11105 O ring bushing 2x 5 EV 11080 Seal disk 6 EV 11082 Spacer narrow 2x 7 EV 11081 Spacer wide 3x 8 EV 11078 Compression spacer...

Страница 30: ...ice flow m hr 4 1 2 1 7 2 3 Rinse water usage per regeneration ltr 295 394 492 Backwash flow rate ltr min 23 31 38 Model PF AG1 Filter media cuft 1 2 3 Service flow rate p 1 bar m hr 3 3 4 3 4 3 5 Rec...

Страница 31: ...6 7 Rinse water usage per regeneration ltr 492 738 984 1 230 1 722 Backwash flow rate ltr min 38 57 76 95 133 Model PF AG1 5 Filter media cuft 3 4 5 7 10 Service flow rate p 1 bar m hr 3 7 8 7 8 7 8...

Страница 32: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com...