COMMISSIONING 

 

 

Page 7 

 

ELECTRICAL 

 
1.

 

Connect  the  appliances power cord  to  the  transformers 
output. 

2.

 

Plug the transformer into an electrical outlet. 

 

PRESSURIZING

 

 
1.

 

Put the bypass system in 'bypass' position. 

2.

 

Make sure the electronic controller of the appliance is in 
service mode. 

3.

 

Open the mains water supply. 

4.

 

Open  a  cold  treated  water  faucet  nearby  the  appliance 
and  let  the  water  run  for  a  few  minutes  until  all  air  is 
purged  and  all  foreign  material  that  may  have  resulted 
from the installation is washed out; close the tap. 

5.

 

Gently pressurize the appliance, by putting it into service: 

 

close the 'BYPASS' valve; 

 

open the 'OUT' valve; 

 

slowly open the 'IN' valve. 

6.

 

After  2-3  minutes,  open  a  cold  treated  water  faucet 
nearby  the  appliance  and  let  the  water  run  for  a  few 
minutes until all air is purged from the installation and the 
filter media is rinsed (it is normal for the rinse water to 
show  some  discoloration!);  let  the  water  run  until  the 
rinse water is clear; close the tap. 

7.

 

Check  the  appliance  and  all  hydraulic  connections  for 
leaks. 

 

ELECTRONIC CONTROL PANEL 

 
1.

 

Program the electronic controller. 

 

INITIATE A REGENERATION 

 
1.

 

Manually initiate  a  regeneration, by pressing  the  scroll 

 button; the display will show: 

 
 
 
2.

 

Leave  the  appliance  in  this  position;  the  count-down 
timer will count down to 0 sec and start a regeneration. 

 
 
 
 

Regen in 10 sec 

Содержание PF-AG1

Страница 1: ...2017 erie water treatment TM EN PF GAC_AG Rev2017 01 Technical Manual WATER FILTER Models PF GAC1 PF AG1 PF GAC1 5 PF AG1 5...

Страница 2: ...Page 12 Default configuration parameter settings Page 13 Composition overview Page 14 Exploded view PF GAC1 PF AG1 System Page 16 Exploded view PF GAC1 PF AG1 Timer assembly Page 18 Exploded view PF...

Страница 3: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Страница 4: ...ATING TEMPERATURE MIN MAX 4 48 C 39 120 F do not install the appliance in an environment where high ambient temperatures e g unvented boiler house or freezing temperatures can occur the appliance cann...

Страница 5: ...uaranteeing uninterrupted supply of water FILTER MEDIA LOADING 1 Move the pressure tank to the correct installation location position it on a flat and level surface Make sure to leave enough space for...

Страница 6: ...f control valve untreated water outlet of control valve treated water 1 Install the 3 valve connection kit 2 Insert the adaptors in the in out ports on the control valve make sure not to damage the O...

Страница 7: ...tting it into service close the BYPASS valve open the OUT valve slowly open the IN valve 6 After 2 3 minutes open a cold treated water faucet nearby the appliance and let the water run for a few minut...

Страница 8: ...the display shows the time of day and the number of days remaining until the next regeneration REGENERATION MODE In regeneration mode the display shows the remaining regeneration time and the remaini...

Страница 9: ...ode All configuration parameters on this appliance have been pre programmed in the factory to offer optimal performance in a wide range of applications and situations Nevertheless it may be necessary...

Страница 10: ...ere shouldn t be any water leakages BYPASSING THE APPLIANCE Occasionally it may be necessary to put the appliance hydraulically in bypass i e to isolate it from the water distribution system f e in ca...

Страница 11: ...essure tank Clean filter media and control valve increase regeneration frequency Plugged lower and or upper distributor Verify that distributors are free of debris Drain line from control valve flows...

Страница 12: ...AL WIRING DIAGRAMS Page 12 PF GAC1 PF AC1 position switches power lead drive motor service valve NO optional key pad PF GAC1 5 PF AC1 5 optical switch power lead drive motor service valve NO optional...

Страница 13: ...ASH min 10 10 10 Cycle 2 SLOW RINSE min 0 0 0 Cycle 3 PURGE min 3 3 3 Regen 0 00 0 00 0 00 Model PF GAC1 5 PF AG1 5 Filter media cuft 3 4 5 7 10 Interval days 4 4 4 4 4 Cycle 1 BACKWASH min 10 10 10 1...

Страница 14: ...N Control valve incl transformer 1 5 male BSP connections Pressure tank incl distributor assy Underbedding Filter media 1 cuft bag cuft model model type ltr type PF GAC1 5 3 35852 EV1 5TF J 100 1 14x6...

Страница 15: ...Page 15...

Страница 16: ...EXPLODED VIEW PF GAC1 PF AG1 SYSTEM Page 16...

Страница 17: ...Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 38534 Riser tube assembly to be cut to length 5 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 28 298 18 Transformer 230 24V 50 Hz...

Страница 18: ...EXPLODED VIEW PF GAC1 PF AC1 TIMER ASSEMBLY Page 18...

Страница 19: ...157 Worm coupling 9 15 222 Screw drive motor assembly 2x 10 74267 Cable clamp 11 70312 Strain relief power lead 12 75158 Retaining ring worm drive shaft 13 72261 Drive motor 14 75156 Worm drive shaft...

Страница 20: ...EXPLODED VIEW PF GAC1 PF AC1 VALVE BODY Page 20...

Страница 21: ...383 Insert plate 14 568 384 Gasket 15 51 5 105 Spring float valve 16 568 270 4 Float valve 17 568 274 5 Injector green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug sm...

Страница 22: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 SYSTEM Page 22...

Страница 23: ...0 BB Coconut Granular Activated Carbon GAC multiple of 1 cuft A8014 Filter Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 39107 Riser tube assembly to be cut to length 5 EV TD Top dis...

Страница 24: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 TIMER ASSEMBLY Page 24...

Страница 25: ...assembly Service Valve 7 74226 Plug large 2x 8 28 244 1 Plug small 9 28 500 11 Power lead with plug incl with transformer 10 EV 20761 Screw optical sensor 2x 11 74235 Optical sensor 12 15 102 Screw P...

Страница 26: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 VALVE BODY Page 26...

Страница 27: ...or 8 74245 Drain Line Flow Controller 10 0 GPM 3 cuft 74246 Drain Line Flow Controller 15 0 GPM 4 cuft 74247 Drain Line Flow Controller 20 0 GPM 5 cuft 74254 Drain Line Flow Controller 25 0 GPM 7 cuft...

Страница 28: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 PISTON ASSEMBLY Page 28...

Страница 29: ...iption Remark 1 EV 20646 Piston 2 EV 20654 Stem 3 EV 11104 Bushing 4 EV 11105 O ring bushing 2x 5 EV 11080 Seal disk 6 EV 11082 Spacer narrow 2x 7 EV 11081 Spacer wide 3x 8 EV 11078 Compression spacer...

Страница 30: ...ice flow m hr 4 1 2 1 7 2 3 Rinse water usage per regeneration ltr 295 394 492 Backwash flow rate ltr min 23 31 38 Model PF AG1 Filter media cuft 1 2 3 Service flow rate p 1 bar m hr 3 3 4 3 4 3 5 Rec...

Страница 31: ...6 7 Rinse water usage per regeneration ltr 492 738 984 1 230 1 722 Backwash flow rate ltr min 38 57 76 95 133 Model PF AG1 5 Filter media cuft 3 4 5 7 10 Service flow rate p 1 bar m hr 3 7 8 7 8 7 8...

Страница 32: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com...

Отзывы: