ELECTRONIC CONTROL PANEL 

 

 

 

Page 8 

  

Picture 9

 

 

symbol 

button 

function 

 

SCROLL 

to advance to the next 

parameter 

 

UP 

to increase the value of the 

parameter 

 

DOWN 

to decrease the value of the 

parameter 

 

POWER-UP 

 
After power-up the  display  will  show  the installed  software 
version for a period of 5 seconds. 
 

POWER FAILURE 

 
In  the  event  of  a  power  failure,  the  program  will  remain 
stored in the NOVRAM® during an undefined period, while an 
incorporated SuperCap will maintain the correct time of day 
during  a  period  of  several  hours;  consequently,  in  case  of 
prolonged  power  failure,  the  time  of  day  might  not  be 
maintained; if this happens, the time of day will be reset to 
8:00  when  the  power  supply  is  re-established,  while  the 
indication will flash, indicating that the time of day needs to 
be set. 
 
When  the  power  failure  occurs  during  the  execution  of  an 
automatic  regeneration,  the  control  valve  will  remain  in  its 
last  position;  when  the  power  supply  is  re-established,  the 
control valve will return to the service position, stay there for 
60  sec.  and  restart  a  complete  regeneration  from  the 
beginning. 
 

TIMER FAILURE 

 
In  the  event  of  a  timer  failure,  the  display  will  show  the 
message: 
 
 
 
If powering off/on the appliance doesn’t solve this problem, 
professional service is required. 
 

MAINTENANCE REMINDER 

 
Once  the  maintenance  interval  is  reached,  the  display  will 
intermittently show the message: 
 
 
 
While the  appliance  will  continue to operate  normally, it is 
recommended  to  have  preventive  maintenance  performed 
by a professional. 
 

SERVICE MODE 

 
In  service  mode  the  display  shows the time  of  day  and the 
number of days remaining until the next regeneration: 

 

REGENERATION MODE 

 
In  regeneration  mode  the  display  shows  the  remaining 
regeneration time and the remaining cycle time: 
 
 
 
The control valve can be reset to service mode at any time by 
pressing the scroll 

 button, as such manually advancing it 

through the regeneration cycles. 
 

MANUAL REGENERATION 

 
It is possible to manually initiate an immediate regeneration 
or  a  delayed  regeneration  (at  the  preprogrammed  time  of 
regeneration).  
1.

 

Press the scroll   button; the display will show: 

 
 
 

 

If  the  control  panel  is  left  in  this  position,  the 
countdown timer will countdown to 0 sec and start an 
immediate regeneration
.  

 

To cancel this mode, press the scroll   button before 
the countdown timer has reached 0 sec; the display 
will show: 

 
 
 

 

If the control panel is left in this position, delayed 
regeneration
  will  be  started  
at  the  indicated 
preprogrammed time of regeneration. 

To cancel this mode, press the scroll 

 button; the control 

panel will return to the service mode 
 

HOLIDAY MODE 

 
It  is  possible to  put  the  appliance in  holiday mode; this  will 
prevent  automatic  regeneration  from  taking  place,  yet  will 
ensure the appliance is automatically regenerated at the end 
of the holiday cycle.  
1.

 

Press  the  scroll 

  button  repeatedly  until  the  display 

shows: 

 
 
 

 

Press  the  up 

  or  down 

  button  to  activate  the 

holiday mode by setting the number of full days away 
from home
, or deactivate the holiday mode (OFF). 

Once  the control  panel  is back  in  service  mode,  the display 
will show:

 

 

 
 
 

 

The  holiday  mode  is  automatically  cancelled  when  a 

regeneration is manually initiated!

 

 

Service Required 

 

Rgn:123 CycY:456

 

Maintenance Now

 

Regen in 10 sec 

Regen @    2:00

 

Holiday: OFF 

 8:01    Holiday 

 8:01  4 DAY REM 

Содержание PF-AG1

Страница 1: ...2017 erie water treatment TM EN PF GAC_AG Rev2017 01 Technical Manual WATER FILTER Models PF GAC1 PF AG1 PF GAC1 5 PF AG1 5...

Страница 2: ...Page 12 Default configuration parameter settings Page 13 Composition overview Page 14 Exploded view PF GAC1 PF AG1 System Page 16 Exploded view PF GAC1 PF AG1 Timer assembly Page 18 Exploded view PF...

Страница 3: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Страница 4: ...ATING TEMPERATURE MIN MAX 4 48 C 39 120 F do not install the appliance in an environment where high ambient temperatures e g unvented boiler house or freezing temperatures can occur the appliance cann...

Страница 5: ...uaranteeing uninterrupted supply of water FILTER MEDIA LOADING 1 Move the pressure tank to the correct installation location position it on a flat and level surface Make sure to leave enough space for...

Страница 6: ...f control valve untreated water outlet of control valve treated water 1 Install the 3 valve connection kit 2 Insert the adaptors in the in out ports on the control valve make sure not to damage the O...

Страница 7: ...tting it into service close the BYPASS valve open the OUT valve slowly open the IN valve 6 After 2 3 minutes open a cold treated water faucet nearby the appliance and let the water run for a few minut...

Страница 8: ...the display shows the time of day and the number of days remaining until the next regeneration REGENERATION MODE In regeneration mode the display shows the remaining regeneration time and the remaini...

Страница 9: ...ode All configuration parameters on this appliance have been pre programmed in the factory to offer optimal performance in a wide range of applications and situations Nevertheless it may be necessary...

Страница 10: ...ere shouldn t be any water leakages BYPASSING THE APPLIANCE Occasionally it may be necessary to put the appliance hydraulically in bypass i e to isolate it from the water distribution system f e in ca...

Страница 11: ...essure tank Clean filter media and control valve increase regeneration frequency Plugged lower and or upper distributor Verify that distributors are free of debris Drain line from control valve flows...

Страница 12: ...AL WIRING DIAGRAMS Page 12 PF GAC1 PF AC1 position switches power lead drive motor service valve NO optional key pad PF GAC1 5 PF AC1 5 optical switch power lead drive motor service valve NO optional...

Страница 13: ...ASH min 10 10 10 Cycle 2 SLOW RINSE min 0 0 0 Cycle 3 PURGE min 3 3 3 Regen 0 00 0 00 0 00 Model PF GAC1 5 PF AG1 5 Filter media cuft 3 4 5 7 10 Interval days 4 4 4 4 4 Cycle 1 BACKWASH min 10 10 10 1...

Страница 14: ...N Control valve incl transformer 1 5 male BSP connections Pressure tank incl distributor assy Underbedding Filter media 1 cuft bag cuft model model type ltr type PF GAC1 5 3 35852 EV1 5TF J 100 1 14x6...

Страница 15: ...Page 15...

Страница 16: ...EXPLODED VIEW PF GAC1 PF AG1 SYSTEM Page 16...

Страница 17: ...Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 38534 Riser tube assembly to be cut to length 5 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 28 298 18 Transformer 230 24V 50 Hz...

Страница 18: ...EXPLODED VIEW PF GAC1 PF AC1 TIMER ASSEMBLY Page 18...

Страница 19: ...157 Worm coupling 9 15 222 Screw drive motor assembly 2x 10 74267 Cable clamp 11 70312 Strain relief power lead 12 75158 Retaining ring worm drive shaft 13 72261 Drive motor 14 75156 Worm drive shaft...

Страница 20: ...EXPLODED VIEW PF GAC1 PF AC1 VALVE BODY Page 20...

Страница 21: ...383 Insert plate 14 568 384 Gasket 15 51 5 105 Spring float valve 16 568 270 4 Float valve 17 568 274 5 Injector green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug sm...

Страница 22: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 SYSTEM Page 22...

Страница 23: ...0 BB Coconut Granular Activated Carbon GAC multiple of 1 cuft A8014 Filter Ag multiple of 1 cuft 3 A1000 Gravel multiple of 25 kg 17 ltr 4 39107 Riser tube assembly to be cut to length 5 EV TD Top dis...

Страница 24: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 TIMER ASSEMBLY Page 24...

Страница 25: ...assembly Service Valve 7 74226 Plug large 2x 8 28 244 1 Plug small 9 28 500 11 Power lead with plug incl with transformer 10 EV 20761 Screw optical sensor 2x 11 74235 Optical sensor 12 15 102 Screw P...

Страница 26: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 VALVE BODY Page 26...

Страница 27: ...or 8 74245 Drain Line Flow Controller 10 0 GPM 3 cuft 74246 Drain Line Flow Controller 15 0 GPM 4 cuft 74247 Drain Line Flow Controller 20 0 GPM 5 cuft 74254 Drain Line Flow Controller 25 0 GPM 7 cuft...

Страница 28: ...EXPLODED VIEW PF GAC1 5 PF AG1 5 PISTON ASSEMBLY Page 28...

Страница 29: ...iption Remark 1 EV 20646 Piston 2 EV 20654 Stem 3 EV 11104 Bushing 4 EV 11105 O ring bushing 2x 5 EV 11080 Seal disk 6 EV 11082 Spacer narrow 2x 7 EV 11081 Spacer wide 3x 8 EV 11078 Compression spacer...

Страница 30: ...ice flow m hr 4 1 2 1 7 2 3 Rinse water usage per regeneration ltr 295 394 492 Backwash flow rate ltr min 23 31 38 Model PF AG1 Filter media cuft 1 2 3 Service flow rate p 1 bar m hr 3 3 4 3 4 3 5 Rec...

Страница 31: ...6 7 Rinse water usage per regeneration ltr 492 738 984 1 230 1 722 Backwash flow rate ltr min 38 57 76 95 133 Model PF AG1 5 Filter media cuft 3 4 5 7 10 Service flow rate p 1 bar m hr 3 7 8 7 8 7 8...

Страница 32: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com...

Отзывы: