RELAY TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTION
18. Control valve regenerates at
A. Power outages > 2 years
A. Reset control valve to correct time of day
wrong time of day
B. Time of day not set correctly
B. Reset to correct time of day
C. Time of regeneration incorrect
C. Reset regeneration time
D. Control valve set at “on 0”
D. Check control valve set-up procedure
(immediate regeneration)
regeneration time option (see page 27)
E. Control valve set at on 0
E. Check control valve set-up procedure
regeneration time option (see page 27)
19. Relay does not energize
A. Relay driver programmed on "Time"
A. Programmed incorrectly
A. Reprogram, see page 11
B. Defective relay, See figure below
B. Replace Relay
C. Defective PC Board
C. Replace PC Board
D. Faulty wire connections between
D. Check and repair wire connections
PC board and relay
B. Relay driver programmed on "Gallons" A. Programmed incorrectly
A. Reprogram, see page 11
B. Faulty meter connection
B. Repair or replace meter assembly
C. Defective relay, See figure below
C. Replace Relay
D. Defective PC Board
D. Replace PC Board
E. Faulty wire connections between
E. Check and repair wire connections
PC board and relay
20. Relay energized during regeneration
A. Relay programmed as "on REGEN
A. Reprogram, see page 11
gallons"
Relay operation while in error modes
1. Relays should turn off immediately whenever a Valve Error occurs.
2. Relays should remain on and continue to operate as programmed
if a MAV Error (1006/1007) occurs and the valve has already en-
tered regen.
3. Relays should remain off, and not operate as programmed, if a
MAV Error (1006/1007) occurs and the valve has not entered regen.
Can be used with DC voltage to power. When utilizing DC voltage, now has a low DC voltage display when voltage drops below
12.05 VDC at a pre-regeneration check. Contact manufacturer for further details.