11
STEP 16S
"REGEN GALLONS"
➔
GAL
SET
STEP 17S
STEP 16 S – REGEN gallons chosen to activate relay. Relay activates after set number of
gallons have been used in service
or
during regeneration and then de-activates after set period of
time or after flow stops, whichever comes first. Press NEXT to go to Step 17S.
SET TIME
➔
MIN
0:01
SET SOFTENING
➔
GAL
1
STEP 17S – Use up and down arrows to select number of gallons per relay activation
of REGEN gallon setting. Range 1–50 gallons. Press NEXT to set relay duration.
Use up and down arrows to set time duration of relay closure. Range 0:01 seconds
- 200:00 minutes.
STEP 18 S – Set duration between scheduled service
reminders.
Use UP & DOWN arrows to select in 1/4 year increments from
1/4 to 9.75 years or on gallons or both or OFF.
Factory Setting = OFF.
To reset call alert, press up & down arrows together for 3
seconds.
STEP 18S
SET TIME
CALL
➔
SET TIME
Yr 0.25
Automatically
Toggles