background image

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any 

guarantee is void in case of improper use. They are not suitable for pumping flammable liquids 

or for use in places where there is danger of an explosion. These pumps are intended for 

 

private use in the home and garden. These pumps are not designed for continuous use (without 

interruptions). In continuous operation mode, the lifetime will be shortened accordingly. Never 

run more than 5 minutes against a closed valve pump. Save the pump against dry running (in-

stall dry run protection). 

Never start and stop the pump more than 20 times per hour. When the pump clocks, any 

claim under warranty is void.

Not suitable for use with solar photovoltaic panels.

English 3

4. INSTALLATION

 

The installation must be performed by a qualified professional.

 

 Please, check each time before using, the electrical connections and the cables are not 

damaged. Check before the installation whether the electrical connections are earthed 

according to the statutory regulations and are installed. The pump is to be secured 

through a RCD circuit breaker with release current of 30 mA. is technically correct, so 

this warranty is void. It must be ensured that the pump is sufficiently cooled during pro-

longed operation.

It is NOT recommended to perform even cable extensions or any other technical modifica-

tions. The lines to the pump must be installed always steadily rising. A transfer of mechani-

cal loads or vibrations from the pump or to the pump must be eliminated through appropriate 

actions (use of rubber buffers, braided hoses, line fixation, etc.). Do not reduce the suction 

line

.

 

All pipe/hose connections to and from the pump must be sealed (e.g. Teflon tape or sealing 

cord - 

no hemp!

)

. Do not reduce the suction line. All pipe/hose connections to and from the pump 

must be sealed. We recommend that you implement the suction line „as one piece“ without any 

interruption in order to prevent and avoid leaks. Check pump and water lines for leaks by pressure 

testing min. 24 hours. 

Is dirt expected  in the pump, an effective pre-filter should be installed 

before the pump inlet. 

Fill pump and suction pipe/hose with water. 

Please connect electrical-

ly pump with power supply. Start the pump. If necessary, the pump and the suction line must 

be refilled until a normal continuous operation has been established.

NOTE: 

Please note that a tapering of the pump connections may cause a defect in the pump. Here, 

the terminal sizes specified should be strictly adhered to. With strong restriction of flowthrough on 

the pressure side of the pump (for example, due to clogged sand filter) water can come out of the 

housing.

5. OPERATION

l

  Please remove the cover of the filler neck, fill in as much water as is necessary to allow it to 

escape from the filler neck, connect the hose sealingly after filling with water.

l

  If the pump is used for self-priming well water, make sure that a non-return valve is installed at 

the front end of the suction line.

l

  Connect the power supply, the display shows „0.0“ bar and the indicator light is on. 

l

  Pump works automatically. Then open the outlet valve in order to remove air from pipes.

l

 Start and stop the pump by press the button „

“ at any operation condition.

l

  By pressing the “ “ or “

“ key, the setpoint value of the working pressure can be set; a short 

press of the “ “ key increases the pressure by 0.1 bar each time. A short press of the “

“ but-

Содержание INVERT-TECH1

Страница 1: ...erungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf www profi pumpe de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG INVERTER AUTOMATIC WATER BOOSTER PUMP HAUSWASSERWERK INVERTER BAUREIHE 1 PS01107 Version 20 12 de Energie sparen Kosten senken Innovation nutzen INVERT TECH1 ...

Страница 2: ...orm 3 RANGES OF APPLICATION These pumps are made for pumping clear water free of mud and sand see technical data The pumps are made for the following ranges of application l In private and in public swimming pool l Circulating large volumes of water l Other Clear water pumping 2 English SAFETY INSTRUCTION AND WARNINGS Please read the user manual before using the device Pull power plug Warning sign...

Страница 3: ...ne fixation etc Do not reduce the suction line All pipe hose connections to and from the pump must be sealed e g Teflon tape or sealing cord no hemp Do not reduce the suction line All pipe hose connections to and from the pump must be sealed We recommend that you implement the suction line as one piece without any interruption in order to prevent and avoid leaks Check pump and water lines for leak...

Страница 4: ...indicator light Indicator light flickers when there is no water in the pipe It will automatically restart after water shortage the restart interval time is 8s 1min 10min 30min 1h 2h 2h recycle 7 Start Stop button Press the button to start stop the pump and to recovery normal state manually when pump is in a state of water shortage 8 Decrease button Press the button one time can reduce 0 1 bar long...

Страница 5: ... The service inter vals are based on the respective usage We recommend a weekly control in much dirt accumulation if necessary daily inspection Under normal pumping conditions the pump requires no servicing From an operating period with clear water of approx 2000 hours the mechanical components should be checked impeller wheels chambers sealing rings etc on wear and if necessary be changed After 3...

Страница 6: ...EPAIRING OF MISTAKES Problem Possible cause Solution Pump runs no wa ter is being pumped Highly fluctuating pressure Air in the suction line Check suction line and connec tions for vacuum tightness Air in the system cannot escape Air in the system must be let out Press RUN key several times for a few minutes Impeller wheel is blocked Impeller wheel must be cleaned Pump does not start or switches i...

Страница 7: ...t our earth THANK YOU FOR YOUR SUPPORT 13 EU DECLARATION OF CONFORMITY The undersigned 1A Profi Handels GmbH Unterriethstr 37 65187 Wiesbaden confirms that the products placed on the market execution referred to the relevant regulations below the rele vant EU directives and harmonized corresponds to the EU standard for security This declaration is valid insofar as no changes to the product are mad...

Страница 8: ...gressive chemische Substanzen vorgesehen Das Wasser muss ggf bis auf 0 2 mm Partikelgröße vorgefiltert werden Für folgende Anwendungsbereiche eignet sich die Pumpe l in privaten sowie in öffentlichen Schwimmbecken l Umwälzen von großen Wassermengen l Sonstige Klarwasserförderung SICHERHEITSHINWEISE UND WARNUNGEN Bitte lesen Sie vor Inbetriebnahme der Pumpe die Bedienungsanleitung Netzstecker ziehe...

Страница 9: ...itungsfixierung usw ausge schlossen werden Wasserleitungen insb die Saugleitung nicht reduzieren Alle Leitungen zu und von der Pumpe dichtend anschließen z B Teflonband oder Dichtfaden kein Hanf Wir empfehlen die Saugleitung stets in einem Stück ohne Unterbrechungen auszuführen um Undichtigkeiten zu vermeiden Pumpe und Wasserleitungen auf Dichtigkeit mittels Druckprüfung mind 24 Std testen Ist mit...

Страница 10: ...manuell gestoppt wird 5 Druckein stellung Die Kontrollleuchte blinkt wenn der Druck eingestellt wird 6 Wasser mangel Kontroll leuchte Die Kontrollleuchte blinkt wenn sich kein Wasser im Leitungs netz befindet Es wird automatisch nach Wassermangel neu gestartet Die Wiederanlaufzeit beträgt 8 Sek 1 Min 10 Min 30 Min 1 Std 2 Std 2 Std Wiederholung 7 Start Stop Taste Drücken Sie die Taste um die Pumpe...

Страница 11: ...en sich nach der jeweiligen Nutzung Wir empfehlen eine wöchentliche Kontrolle bei viel Schmutzanfall ggf tägliche Kontrolle Unter normalen Betriebsbedingungen erfordert die Elektropumpe keine weitere Wartung Ab einer Betriebsdauer bei Klarwasser von ca 2000 Stunden sollten die mechanischen Bauteile wie Laufräder Laufkammern Dichtungen etc auf Unversehrtheit hin überprüft und ggf getauscht werden N...

Страница 12: ...en die weitere Vorgehensweise fallbezogen mit Rücksendungen bitte ausreichend frankieren Unfreie Rücksendungen können leider nicht angenom men werden da diese vor Zustellung rausgefiltert werden Unsere Serviceleistung erbringen wir in Deutschland Die Garantie gilt nicht bei l Materialverschleiß z B Dichtungen Laufräder Laufkammern l Unberechtigten Eingriffen oder Veränderungen an der Pumpe l Besch...

Страница 13: ...timmungen den entsprechenden EU harmonisierten Richtlinien und dem EU Standard für Sicherheit entspricht Diese Konformitätserklärung gilt insofern an dem Produkt keine Veränderungen vorgenommen werden Richtlinie Niederspannung 2014 35 EG Richtlinie Elektromagnetische Verträglichkeit 2014 30 EU Folgende harmonisierte Normen EN 60335 2 41 2003 A1 2004 A2 2010 EN 60335 1 2012 A11 2014 A13 2017 EN 622...

Страница 14: ...12 Notes Notizen Performed service work as precise and detailed as possible Ausgeführte Servicearbeiten so präzise und detailliert wie möglich Signature Unterschrift Date Datum Name Service Person ...

Страница 15: ...13 Notes Notizen ...

Страница 16: ...stallations Schema English Deutsch PS01107 Power P1 Leistung P1 800 W Max pump capacity Max Fördermenge 3 7 m h Max pressure Max Druck 4 5 bar Max pump height Max Förderhöhe 45 m Max water temperature Max Wassertemperatur 60 C Protective class Schutzklasse IPX5 Tension Spannung 230V 50 Hz Measures in mm Maße in mm 300x187x282 Connection in out Anschlüsse 1 Cable length Kabellänge 1 5 m Schematic i...

Отзывы: