background image

English 5

7. SECURITY TIPS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping inflammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

 Never pull the pump on the electrical cable or pressure hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size 

 

l

  During longer unused times, clean the pump, wash it out with clear water, dry and store it 

at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

  The pump is to be secured through a RCD circuit  breaker with a release current of 30 mA.

 

l

 The electrical connections are always to be carried out by an authorised professional

l

  The pump may be used by children aged 8 years and above as well as persons with reduced 

physical, sensory or mental abilities or those who lack skills, experience and knowledge only if 

they are supervised. These aforementioned persons should only use the appliance while adhe-

ring to safe instructions and resulting dangers.

l

  Cleaning and maintenance must not be carried out by children without supervision.

l

  Under certain cirumstances, it is possible that that contamination of water is caused by leakage.

THE MANUFACTURER EXPLAINS:

l

  To take over no responsibility in the case of accidents or damages on the basis of careless-

ness or disregard to the instructions in this book.

l

  To reject every responsibility for the damages which originate from the improper use of the pump.

8. SERVICING

 

 It must be regularly checked the pump filter and clean if necessary. The service inter-

vals are based on the respective usage. We recommend a weekly control in much dirt 

accumulation, if necessary daily inspection. Under normal pumping conditions the pump 

requires no servicing. From an operating period (with clear water) of approx. 2000 hours 

the mechanical components should be checked: impeller wheels, chambers, sealing 

rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in 

the chamber should also be changed, if necessary (only with oil-dipped engine types!). 

Please, only fill it up to 80% and check the sealing rings always for density.

 

With abrasive materials like sand the servicing duration can become shorter.

 

The following controls should be carried out regularly:

 

l

 Intactness of the electric cable

 

l

 That the connection hoses are not bent or broken

 

l

 Cleanness of the pump medium 

 

 Moreover, the pump should be emptied with risk of frost, be washed out with clear water 

and stored dry.

Fault code description

NO.  Name of code

Code 

Fault cause

7  Overcurrent/Short Circuit 

Protection

oLP 

This code appears when the motor is overcurrent/short circuit and it should be  

troubleshooting manually.

8  Communication Failure  

Protection

EAA 

This code appears when the communication failure occurred between drive board 

and control board and it should be troubleshooting manually.

Locked-rotor Protection

EH 

This code appears when the rotor is locked and it should be troubleshooting manually.

10  Lost Phase Protection

EP 

This code appears when phase is lost and it should be troubleshooting manually.

11 

Leakage Protection

LL 

When the pump runs continuously for 4 hours, it automatically enters the protection 

program. After eliminating leakage or confirming that it works properly, it can be 

restarted by changing parameters or power off.

Содержание INVERT-TECH1

Страница 1: ...erungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf www profi pumpe de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG INVERTER AUTOMATIC WATER BOOSTER PUMP HAUSWASSERWERK INVERTER BAUREIHE 1 PS01107 Version 20 12 de Energie sparen Kosten senken Innovation nutzen INVERT TECH1 ...

Страница 2: ...orm 3 RANGES OF APPLICATION These pumps are made for pumping clear water free of mud and sand see technical data The pumps are made for the following ranges of application l In private and in public swimming pool l Circulating large volumes of water l Other Clear water pumping 2 English SAFETY INSTRUCTION AND WARNINGS Please read the user manual before using the device Pull power plug Warning sign...

Страница 3: ...ne fixation etc Do not reduce the suction line All pipe hose connections to and from the pump must be sealed e g Teflon tape or sealing cord no hemp Do not reduce the suction line All pipe hose connections to and from the pump must be sealed We recommend that you implement the suction line as one piece without any interruption in order to prevent and avoid leaks Check pump and water lines for leak...

Страница 4: ...indicator light Indicator light flickers when there is no water in the pipe It will automatically restart after water shortage the restart interval time is 8s 1min 10min 30min 1h 2h 2h recycle 7 Start Stop button Press the button to start stop the pump and to recovery normal state manually when pump is in a state of water shortage 8 Decrease button Press the button one time can reduce 0 1 bar long...

Страница 5: ... The service inter vals are based on the respective usage We recommend a weekly control in much dirt accumulation if necessary daily inspection Under normal pumping conditions the pump requires no servicing From an operating period with clear water of approx 2000 hours the mechanical components should be checked impeller wheels chambers sealing rings etc on wear and if necessary be changed After 3...

Страница 6: ...EPAIRING OF MISTAKES Problem Possible cause Solution Pump runs no wa ter is being pumped Highly fluctuating pressure Air in the suction line Check suction line and connec tions for vacuum tightness Air in the system cannot escape Air in the system must be let out Press RUN key several times for a few minutes Impeller wheel is blocked Impeller wheel must be cleaned Pump does not start or switches i...

Страница 7: ...t our earth THANK YOU FOR YOUR SUPPORT 13 EU DECLARATION OF CONFORMITY The undersigned 1A Profi Handels GmbH Unterriethstr 37 65187 Wiesbaden confirms that the products placed on the market execution referred to the relevant regulations below the rele vant EU directives and harmonized corresponds to the EU standard for security This declaration is valid insofar as no changes to the product are mad...

Страница 8: ...gressive chemische Substanzen vorgesehen Das Wasser muss ggf bis auf 0 2 mm Partikelgröße vorgefiltert werden Für folgende Anwendungsbereiche eignet sich die Pumpe l in privaten sowie in öffentlichen Schwimmbecken l Umwälzen von großen Wassermengen l Sonstige Klarwasserförderung SICHERHEITSHINWEISE UND WARNUNGEN Bitte lesen Sie vor Inbetriebnahme der Pumpe die Bedienungsanleitung Netzstecker ziehe...

Страница 9: ...itungsfixierung usw ausge schlossen werden Wasserleitungen insb die Saugleitung nicht reduzieren Alle Leitungen zu und von der Pumpe dichtend anschließen z B Teflonband oder Dichtfaden kein Hanf Wir empfehlen die Saugleitung stets in einem Stück ohne Unterbrechungen auszuführen um Undichtigkeiten zu vermeiden Pumpe und Wasserleitungen auf Dichtigkeit mittels Druckprüfung mind 24 Std testen Ist mit...

Страница 10: ...manuell gestoppt wird 5 Druckein stellung Die Kontrollleuchte blinkt wenn der Druck eingestellt wird 6 Wasser mangel Kontroll leuchte Die Kontrollleuchte blinkt wenn sich kein Wasser im Leitungs netz befindet Es wird automatisch nach Wassermangel neu gestartet Die Wiederanlaufzeit beträgt 8 Sek 1 Min 10 Min 30 Min 1 Std 2 Std 2 Std Wiederholung 7 Start Stop Taste Drücken Sie die Taste um die Pumpe...

Страница 11: ...en sich nach der jeweiligen Nutzung Wir empfehlen eine wöchentliche Kontrolle bei viel Schmutzanfall ggf tägliche Kontrolle Unter normalen Betriebsbedingungen erfordert die Elektropumpe keine weitere Wartung Ab einer Betriebsdauer bei Klarwasser von ca 2000 Stunden sollten die mechanischen Bauteile wie Laufräder Laufkammern Dichtungen etc auf Unversehrtheit hin überprüft und ggf getauscht werden N...

Страница 12: ...en die weitere Vorgehensweise fallbezogen mit Rücksendungen bitte ausreichend frankieren Unfreie Rücksendungen können leider nicht angenom men werden da diese vor Zustellung rausgefiltert werden Unsere Serviceleistung erbringen wir in Deutschland Die Garantie gilt nicht bei l Materialverschleiß z B Dichtungen Laufräder Laufkammern l Unberechtigten Eingriffen oder Veränderungen an der Pumpe l Besch...

Страница 13: ...timmungen den entsprechenden EU harmonisierten Richtlinien und dem EU Standard für Sicherheit entspricht Diese Konformitätserklärung gilt insofern an dem Produkt keine Veränderungen vorgenommen werden Richtlinie Niederspannung 2014 35 EG Richtlinie Elektromagnetische Verträglichkeit 2014 30 EU Folgende harmonisierte Normen EN 60335 2 41 2003 A1 2004 A2 2010 EN 60335 1 2012 A11 2014 A13 2017 EN 622...

Страница 14: ...12 Notes Notizen Performed service work as precise and detailed as possible Ausgeführte Servicearbeiten so präzise und detailliert wie möglich Signature Unterschrift Date Datum Name Service Person ...

Страница 15: ...13 Notes Notizen ...

Страница 16: ...stallations Schema English Deutsch PS01107 Power P1 Leistung P1 800 W Max pump capacity Max Fördermenge 3 7 m h Max pressure Max Druck 4 5 bar Max pump height Max Förderhöhe 45 m Max water temperature Max Wassertemperatur 60 C Protective class Schutzklasse IPX5 Tension Spannung 230V 50 Hz Measures in mm Maße in mm 300x187x282 Connection in out Anschlüsse 1 Cable length Kabellänge 1 5 m Schematic i...

Отзывы: