![Prodys ProntoNet Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/prodys/prontonet/prontonet_user-manual_1609710010.webp)
Prontonet IP Decoder User Manual v5.4.1.1.doc
10
II.3.3
RS 232 Port
There is one RS232 port for use as auxiliary data port. This port allows the
reception of data along with encoded audio. Note that this socket is RJ45
connection, as opposed to the typical sub-D 9 ways connectors. To make the
conversion between RJ45 and RS232 there are modular connectors available that
should be wired as follows:
S-Cluster
RJ45
Connector
9-pin female
D-sub
Connector
1 (NC)
1
2 (Rx)
3
3 (GND)
5
4 (NC)
4
5 (NC)
6
6 (GND)
7
7 (Tx)
2
8 (NC)
8
1,4,5,8 must be unconnected
The port is always set to 8 DATA bits, NO parity, 1 START bit and 1 STOP bit.
The bit rate can be adjusted to between 300 and 9600 bps via software.
The ProntoNet IP Decoder acts as a DCE device, therefore the connection to
each of the RS232 ports is wired in the following way:
ProntoNet IP Decoder – Pin 7 connector RJ45.........................Pin 2 PC
ProntoNet IP Decoder – Pin 2 connector RJ45.........................Pin 3 PC
ProntoNet IP Decoder – Pin 3,6 connector RJ45......................Pin 5 PC
The ProntoNet IP Decoder ignores hardware handshaking signals.